Electrical Connections - Renishaw RGH34 Installation Manual

Linear encoder system
Table of Contents

Advertisement

Electrical connections

Grounding and shielding
Conductive
Output
shield
signals
FPC Cable
Conductive
RGH34
mounting plate
readhead
*
Maximum extension cable length
RGI34B-100 m, RGI34T, D, G and X - 50 m, RGI34N, W, Y and H - 20 m
For optimum performance, ensure 100% screening
Ground the readhead mounting bracket
Ensure continuity of all shields
Use double shielded extension cable
Connect interface CASE to ground
Use shielded connector shells on all cable connections
Terminate the inner shield to 0V power at the customer interface
Maximise the distance between encoder and motor cables
RGH34 RGS40 installation guide
Double-shielded extension cable
Outer shield
Inner shield
0 V
Interface 'case'
connected to
Case
ground
Recommended signal termination
Digital outputs - RGI34T, D, G, X, N, W, Y and H
*
Interface
A B Z Q+
= 120 Ω
Cable Z
0
A B Z Q-
Standard RS422A line receiver circuitry
Capacitors recommended for improved noise immunity.
Analogue output - RGI34B
V
V
V
+
0
1
2
120 Ω
V
V
V
-
0
1
2
Remote LED driver outputs
The remote LED driver output allows remote monitoring of readhead installation.
150 Ω
Green
+
Green
Red
0 V
Customer
220 pF
electronics
120 Ω
220 pF
0 V
Red/Green
LED
Red
10

Advertisement