Commissioning - Dimplex ECSd125-580 Installation And User Instructions Manual

Direct electric and indirect cylinders up to 300l. ec-eau cylinder range
Table of Contents

Advertisement

6 Commissioning

At
the
time
of
complete all relevant sections of the
Benchmark Checklist located on the
inside back pages of this document.
The
following
procedures only detail the required
steps to be taken for the potable water
loop:
1)
Before
making
connections to the inlet control
group, flush the mains pipework
out to ensure all debris has been
removed so as not to damage the
strainer within the combination
valve.
2)
Make final mains connection on
combination valve and check all
connections and joints to ensure
they have been tightened and
secured correctly.
3)
Before
turning
supply to the cylinder a hot water
tap should be opened, preferably
on the same floor or the floor
below
where
located.
4)
Check
the
pre-charge
expansion vessel and ensure it is
at
least
3
pressure on label on expansion
vessel.
5)
Turn on the supply to the cylinder
and fill until water runs from the
open hot water tap. Continue to
flush the system until all debris
has been removed.
commissioning,
commissioning
any
mains
on
the
mains
the
cylinder
is
in
the
bar.
Note
actual
Commissioning
6)
Close the hot water tap.
7)
Check all joints for leaks, even
those not having been altered
especially when replacing a vented
cylinder.
8)
Open temperature and pressure
relief
valve
discharge and check after closing
that valve is not dripping.
9)
Open expansion relief valve to
ensure
proper
check after closing that valve is
not dripping.
10) Check all shower outlets, toilet
cisterns and other draw off points
for leaks or dripping (especially
when replacing a vented unit).
Open all water outlets to purge air
from pipe work and ensure proper
operation.
11) Adjust
immersion
thermostat in accordance with
client requirements.
12) Instruct user in the operation of
the unit and hand over this manual
advising the owner of annual
service requirements.
13) Complete the technical data label
on the cylinder with legible and
permanent writing.
to
ensure
proper
discharge
and
heater

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecsd250-580Ecsd150-580Ecsd210-580Ecsd300-580

Table of Contents