Installation After Maintenance; Drive And Motor; Recommended Lubricants For Enclosed Gear; Reducers - Graco LubeMaster Instructions Manual

Floor mount or wall mount pump package
Table of Contents

Advertisement

Maintenance and Repair
Output Manifold Repair Kit 563916
See instructions included with repair kit for procedure.
Seal Repair Kit 563921
See instructions included with repair kit for procedure.

Installation After Maintenance

After pump maintenance has been accomplished, per-
form the following procedure to return the unit to service.
1. Locate the pump body and assembled parts at the
position from which it was removed and secure with
attaching hardware. Make certain all fasteners are
tightened to the proper torque.
2. Install all guards and mechanical linkages or con-
nections removed at the pump drive shaft.
3. Install the reservoir.
4. Electrically reconnect the pump drive.
5. Replace drain plug (116).

Drive and Motor

There is little maintenance required on the clutch drive.
The clutch drive assembly replacement part number
563383 is available from Graco. Contact your local
Graco distributor for assistance in ordering this part.
24
Recommended Lubricants for
Enclosed Gear Reducers
AMBIENT
RECOMMENDED
(Room)
OIL (or equiva-
TEMP
lent)
-30° to 225° F**
MOBIL SHC 634*
(-34° to 107°C)
SYNTHETIC
40° to 90° F
MOBIL 600W
(4.4° to 32.2°C)
CYLINDER OIL
80° to 125° F
MOBIL EXTRA
(26.7° to
HECLA SUPER
51.7°C)
CYLINDER OIL
The gear reducer requires 7.8 ounces (230.7 ml) of
clean lubricant as listed above.
The lubricant must remain free from oxidation and con-
tamination by water or debris, since only a very thin film
of oil stands between efficient operation and failure. To
assure long service life, the reducer should be periodi-
cally drained (preferably while warm) and refilled to the
proper level with a recommended gear oil. Under normal
environmental conditions oil changes are suggested
after the Alternative AGMA Lubricants initial 250 hours
of operation and thereafter at regular intervals of 2500
hours or every 6 months.
Synthetic lubricants will allow extended lubrication inter-
vals due to its increased resistance to thermal and oxi-
dation degradation. It is suggested that the initial oil
change be made at 1,500 hours and, thereafter, at
5,000 hour intervals.

Alternative AGMA Lubricants

MANUFACTURER LUBRICANT NAME
Getty Refining Co.
Veedol Asreslube 98
Getty Refining Co.
Veedol Asreslube 95
Getty Refining Co.
Veedol Asreslube 90
Lubrication Engr.
Almasol 609
Inc.
Almasol 608
Lubrication Engr.
Inc.
Mobil Oil Corp.
Mobilgear 634
Mobil Oil Corp.
Mobil Extra Hecia Super
Mobil Oil Corp.
Mobil Cylinder 600W
Shell Oil Co.
Omala 460
Shell Oil Co.
Valvala J460
Shell Oil Co.
Omala 680
Valvala J680
Texaco Inc.
Meropa 680
Texaco Inc.
Meropa 460
VISCOSITY
LUBRI-
ISO
RANGE SUS
CANT
VISCOSITY
@ 100° F
AGMA NO.
GRADE NO.
(38°C)
+
1950/2150
---
320/460
1920/3200
7 or 7C
460
2850/3600
8 or 8C
680
AGMA RATING
8 EP
7 EP
6 EP
8
7
8 EP
8
7
7 EP
7
8 EP
8
8 EP
7 EP
3A2781A

Advertisement

Table of Contents
loading

Table of Contents