LubeMaster® Floor Mount or Wall Mount Pump Package
Motors (56 C-face)
* These recommended operating temperatures are based on materials used in construction of the pump and
reservoir only.
** The grease must be pumpable at the lowest anticipated operating temperature.
®
Loctite
is a registered trademark of the Loctite Corporation.
36
US
115/230V 1/2 hp single phase 60 Hz 1725 RPM, T.E. Full load run-
ning current 115 Volts, 7.4 Amps; 230 Volts, 3.7 Amps. Inrush at
115 Volts 49 AMPS; 230 Volts 24.5 AMPS.
230/460V 1/2 hp three phase 60 Hz 1725 RPM, T.E. Full load run-
ning current 230 Volts, 2 Amps; 460 Volts, 1 Amp. Inrush at 230
Volts 12.2 AMPS; 460 Volts 6.1 AMPS.
115/230V 1/2 hp single phase 60 Hz 1140 RPM, T.E. Full load run-
ning current 115Volts, 7.8 Amps; 230 Volts, 3.9 Amps. Inrush at
115 Volts 49 AMPS; 230 Volts 24.5 AMPS.
230/460V 1/2 hp three phase 60 Hz 1140 RPM, T.E. Full load run-
ning current 230 Volts, 2.4 Amps; 460 Volts, 1.2 Amps. Inrush at
230 Volts 12.2 AMPS; 460 Volts 6.1 AMPS.