C. Settings and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage.
1. Default Dip Switch Settings
The dip switch is factory-adjusted to the following positions:
S1 Dip Switch No.
KM-230BAJ
OFF OFF OFF OFF
KM-300BAJ
OFF OFF OFF OFF
KM-300BWJ
OFF OFF OFF OFF
S2 Dip Switch No.
KM-230BAJ
ON
KM-300BAJ
ON
KM-300BWJ
ON
Do not adjust the S2 dip switch. These must be left in the factory default position, or
the unit will not operate properly. The S2 dip switch No. 6 is factory-adjusted to the
"ON" position for the auxiliary codes G1 and H0. Change it to the "OFF" position when
replacing the control board. This does not affect the product performance but prevents
cloudy ice even in poor water quality areas.
S1 Dip Switch
Harvest Pump Timer (7 & 8)
Pump-Out Frequency Control
(5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Fig. 4
2. Harvest Timer (S1 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reached 48°F (9°C) at the
evaporator outlet and the control board reads 3.9 kΩ from the thermistor. The harvest
NOTICE
1
2
3
4
1
2
3
4
OFF OFF OFF OFF
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
Freeze Timer (9 & 10)
5
6
7
ON
ON
OFF
ON
ON
ON
OFF OFF
ON
ON
ON
OFF
5
6
ON
S2 Dip Switch
Fig. 5
33
8
9
10
ON
OFF
ON
ON
ON
OFF
Anti-Slush Control (6)
Overfreeze Detection Control (5)
Harvest Completion Detection
Control (4)
Refill Counter (3)
Harvest Promotion Control (2)
Pump-Out/Drain Selector (1)