C. Settings and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch No.
KMH-2100SWJ3
KMH-2100SRJ3
KMH-2100SRJ
S5 Dip Switch (Do Not Adjust)
S5 Dip Switch No. 1
All
S4 Dip Switch
1
2
3
4
OFF OFF OFF OFF OFF OFF ON OFF ON OFF
OFF OFF OFF OFF ON OFF ON OFF OFF OFF
2
3
4
5
OFF OFF OFF OFF ON
S4 Dip Switch
Freeze Timer (9 & 10)
Factory Use (8)
Harvest Pump Time (Harvest Assist) and Freeze-Time Correction (7)
(Do Not Adjust)
Harvest Pump Time Timer (Harvest Assist Duration) (6)
Pump-Out Frequency Control (5)
Pump-Out Time (3 & 4)
Harvest Timer (1 & 2)
S5 Dip Switch (
NOTICE
5
6
7
8
9
Do Not Adjust)
Anti-Slush (5)
Minimum Harvest Time (4)
Refill Counter (2 and 3)
Float Switch Selector (1)
38
10