8-1. Connecting a power supply
- Connect +12V of power supply to Red wire.
- Connect GND of power supply to Black wire.
8-2. Connecting a door lock
- Connect (+) wire of door lock to +12V wire of power supply.
- Connect (-) wire of door lock to white wire of reader module.
8-3. Connecting an exit button
- Connect Green wire of exit button input to one wire between wires of exit button.
- Connect GND wire of power supply to the other wire.
8-4. Connecting a door sensor
- Connect COM terminal of door sensor to Blue wire of door sensor input.
- Connect NO terminal of door sensor to GND of power supply.
8-5. Connecting a door lock type
- In a power fail safe, connect GND wire of power supply to Yellow wire of door lock type input.
- In a power fail secure, put a floating state on Yellow wire of door lock type input.
8-6. RS485 Communication port connection
The INC300 for RS485/RS232 converter is required to connect a product to the PC.
- Connect gray wire for RS485(A) to 485(+) terminal of converter.
- Connect orange wire for RS485(B) to 485(-) terminal of converter.
- Plug 9-pin connector of converter into COM Port of the PC.
- Install the application software and then run.
COM Port of the PC
RS232/RS485 Converter
Orange wire
Gray wire
485 (-)
485 (+)