10 Technical data
Name
For supplying
Design
Configuration
Capacity
Dimensions
Width
Height
Depth
Weight when filled with water
Draw-off volume - partial load
Draw-off volume - full load
Switch-on flow pressure, partial
load
Switch-on flow pressure, full
load
Outlet temperatures at 10 °C
for output selector level II
Partial load
Full load
Outlet temperatures at 10 °C
for output selector level I
Partial load
Full load
Measuring record for
output selector level II
Partial load*
Full load* (T of 37 K)
Measuring record for
output selector level I
Partial load*
Full load* (T of 25 K)
Rated overpressure
Measuring voltage
Measuring frequency
Minimum water resistance
Safety
Level of protection
Tab. 10.1 Technical data
1) = Closed unit (pressure resistant)
* at 380/400 V
Installation instructions for VED electric instantaneous water heater 0020149586_00
Unit
VED H 12/7
0010007731
one or more draw-off points
Appliance for wall-mounted installation
Bare wire heating coil
l
0.4
mm
240
mm
481
mm
100
kg
4.4
l/min
2.7
l/min
3.8
MPa
0.020
MPa
0.035
°C
°C
°C
°C
kW
5.2/6.0
kW
12/10.3
kW
3.4/4.0
kW
6.9/8.0
MPa
V
Hz
cm
Complies with German and Austrian safety regulations; radio-shielded;
does not interact with the mains supply
IP 25 = sprayed-water protection
VED H 18/7
VED H 21/7
0010007732
0010007733
1)
3.8
4.4
5.8
6.7
0.030
0.035
0.055
0.070
40
50
30
40
7.8/9.0
9.1/10.5
18/15.5
18.1/21.0
5.2/6.0
6.0/7.0
10.3/12.0
12.1/14.0
1
3/PE~ 380/400
50 Hz
900
Technical data 10
VED H 24/7
VED H 27/7
0010007734
0010007735
5.1
5.7
7.7
8.6
0.040
0.045
0.090
0.100
10.4/12.0
11.6/13.5
20.7/24.0
23.3/27.0
6.7/8.0
7.8/9.0
13.8/16.0
15.5/18.0
17