For the operator
Operating instructions
Publisher/manufacturer
Vaillant GmbH
Berghauser Str. 40
D-42859 Remscheid
Tel. +49 21 91 18‑0
Fax +49 21 91 18‑2810
info@vaillant.de
www.vaillant.de
ecoFIT pure
612 - 630
Operating instructions
GB, IE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecoFIT pure 612 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vaillant ecoFIT pure 612

  • Page 1 Operating instructions For the operator Operating instructions ecoFIT pure 612 - 630 GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810 info@vaillant.de www.vaillant.de...
  • Page 2: Table Of Contents

    Contents Contents Troubleshooting ......13 Detecting and rectifying faults..13 Safety ..........3 Calling up (Live monitor) status Action-related warnings ....3 codes ........... 13 Intended use ........3 Care and maintenance ....14 General safety information..... 4 Maintenance ........ 14 Notes on the documentation ..
  • Page 3: Safety

    Safety 1 1 Safety ing installations and for hot wa- ter generation. 1.1 Action-related warnings Intended use includes the fol- Classification of action-re- lowing: lated warnings – observance of the operating The action-related warnings instructions included for the are classified in accordance product and any other system with the severity of the pos- components...
  • Page 4: General Safety Information

    1 Safety ▶ Do not use any electrical 1.3 General safety information switches, mains plugs, door- bells, telephones or other 1.3.1 Installation by communication systems in competent persons only the building. The installation, inspection, ▶ If it is safe to do so, close the maintenance and repair of the emergency control valve or product, as well as the gas ratio...
  • Page 5 Safety 1 1.3.5 Risk of death due to 1.3.7 Risk of corrosion explosive and flammable damage due to materials unsuitable combustion and room air ▶ Do not use or store explosive or flammable materials (e.g. Sprays, solvents, chlorinated petrol, paper, paint) in the in- cleaning agents, paint, adhes- stallation room of the product.
  • Page 6 1 Safety 1.3.9 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all ▶ Never attempt to carry out maintenance work or repairs on your product yourself. ▶ Faults and damage should be immediately rectified by a competent person.
  • Page 7: Notes On The Documentation

    Notes on the documentation 2 2 Notes on the 3.2 Control elements documentation 2.1 Observing other applicable documents ▶ You must observe all operating instruc- tions enclosed with the system compon- ents. 2.2 Storing documents ▶ Keep this manual and all other applic- Fault clearance Operating but- able documents safe for future use.
  • Page 8: Displayed Symbols

    3 Product description Maximum out- Current assign- Sym- Meaning Explanation put (only used ment of the left- for Austria, hand selection Burner anti-cyc- To avoid the Germany and button ling time is active need for frequent Switzerland) Active operating switching on and Access to the status off (increases the...
  • Page 9: Serial Number

    Product description 3 3.7 Benchmark Information Meaning on the identi- Vaillant is a licensed member of the fication plate Benchmark Scheme. Maximum water pressure in Benchmark places responsibilities on both heating mode manufacturers and installers. The purpose Maximum water pressure in...
  • Page 10: Operation

    4 Operation 4 Operation button, the activated function is displayed in the display. 4.1 Operating concept The functions that are available depend on whether a controller is connected to the Function product. erator control You can switch back to the basic display element –...
  • Page 11: Starting Up The Product

    Operation 4 4.9 Setting the hot water Applicability: Product with connected domestic hot water cylinder temperature ▶ Open the cold water stop valve. Warning. Risk of being scalded by hot 4.6 Starting up the product water. ▶ Only start up the product once the cas- To protect against Legionella, ing has been completely closed.
  • Page 12: Guaranteeing The Correct Filling Pressure Of The Heating System

    4 Operation 3. Confirm by pressing The filling pressure is in the intended ◁ pressure range. Heating mode is switched off. ◁ 2 / 2 symbol appears in the Filling pressure: < 0.08 MPa display. (< 0.80 bar) ▶ 4.11 Guaranteeing the correct Fill the heating installation.
  • Page 13: Protecting The Heating Installation Against Frost

    Troubleshooting 5 8. Check the filling pressure in the anteed by completely draining the heating installation and the product. display. ▶ 9. Top up with more water if necessary. Consult a competent person about this. 10. Close the filling cock. 4.13 Switching the product to 11.
  • Page 14: Care And Maintenance

    6 Care and maintenance You must not be able to see or feel any obstructions in the condensate drain pipe- work and tundish. 6 Care and maintenance ▶ If you notice a fault, have it rectified by 6.1 Maintenance a competent person. An annual inspection of the product carried out by a competent person is a prerequis- 7 Decommissioning...
  • Page 15: Guarantee And Customer Service

    9.2 Customer service To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions for further details: Telephone: 0330 100 3461 0020230534_02 ecoFIT pure Operating instructions...
  • Page 16: Appendix

    Appendix Appendix A Status codes – Overview Status codes that are not listed here can be viewed in the installation instructions. Status Parameter Meaning code Displays in heating mode S.00 Heating: No heat demand Heating: No heat demand S.02 Heating mode: Pump pre-run Heating mode: Pump pre-run S.03 Heating mode: Ignition...
  • Page 17 Appendix Fault Cause Measure Product does not The system pressure is insufficient. Fill the heating installation (→ start up: "Filling the heating installation" Low water pressure in the heating in- section). stallation (fault message: F.22). – No hot water There is air in the heating installation. Have your competent person –...
  • Page 20 0020230534_02 0020230534_02 05.08.2019 supplier Vaillant Ltd. Nottingham Road Belper Derbyshire DE56 1JT Telephone 0330 100 3461 info@vaillant.co.uk www.vaillant.co.uk © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent. We reserve the right to make technical changes.

Table of Contents