Modifications / Changes / Spare Parts; Stoppages - Judo GUBi-E Installation And Operating Instructions Manual

Table of Contents

Advertisement

ATTENTION
(See chapter on "Safety information and
dangers due to non-compliance")
If the interval until the next backwashing is
longer than two months, the particles on the
filter screen can stick or a large filter pres-
sure resistance can result.
Unauthorised persons must not operate the
Domestic Water station! Persons who oper-
ate the Domestic Water station must ob-
serve the operating instructions. Failure to
observe these instructions can result in
damage to property and personal injuries.
From experience, increased dirt is deposit-
ed during the initial running period. In this
case the unit will have to be flushed more
frequently than normal.
Failure to flush in good time can cause dam-
age to the screen. Large quantities of filtered
particles can deform the screen. As a result,
proper function of the Domestic Water sta-
tion is no longer ensured. In addition, large
quantities of dirt can cause mechanical
damage to the backwashing function.
Operation
5.5
Modifications / changes /
spare parts
ATTENTION
(See chapter on "Safety information and
dangers due to non-compliance")
Only original spare parts are to be used!
Independent modifications and changes are
prohibited for safety reasons! These can im-
pair the function of the Domestic Water sta-
tion, lead to lead and in extreme cases can
cause the Domestic Water station to burst.
The test marks imprinted on the unit are only
valid if original spare parts are used.
5.5.1 Servicing / Repair
Before carrying out any work on the Domes-
tic Water, which extends beyond pure oper-
ational control, the Domestic Water must be
depressurised! Failure to observe this can
lead to an uncontrolled escape of water and
therefore lead to water damage in the build-
ing. Strictly comply with the instructions giv-
en in the "Installation" and "Maintenance"
chapters.
5.6

Stoppages

ATTENTION
(See chapter on "Safety information and
dangers due to non-compliance")
If a Domestic Water station has to be re-
moved from the flange or unscrewed, the
chapter "Intended use" must always be ob-
served!
– Protect the flange surfaces from dam-
age! Damaged flanged surfaces cannot
close tight. As a result, escaping water
can damage the building and installa-
tions.
– Ensure that no dirt can get into the Do-
mestic Water station! This dirt can get in-
to contact with and be discharged into
JUDO GUBi-E