Internal
+3.3V
Relay Type
3). Alarm (DO1 | DO2) connection: Only the relay type is supported.
Digital Output 1
Relay Rating: Max 30VDC 1A
Normally Open (N.O) at power off
Digital Output 2
Relay Rating: Max 30VDC 1A
Normally Closed (N.C) at power off
CAUTION:
Do not exceed the maximum relay rating.
4). LAN connection: This is a RJ45 LAN connector for 10/100 Base-T Ethernet. Use the Ethernet cable
(RJ45) to connect the device to a hub or a router in the network. Refer to Section 7:
Ethernet Specifications
5). Power Connection: The camera can be powered by either 12VDC or PoE. If the camera is powered
via PoE, you do not need to connect the power adaptor. For more information about PoE, refer to
Section 7:
Power over Ethernet Specifications
NOTES:
Temperature criterion for the heater operation: 0˚C (32˚F)
Lowest temperature to guarantee the heater operation during the device operation: -40˚C (-40˚F)
Lowest temperature to boot up the device when the device is powered on:
0˚C (32˚F)