Cheetah Pregius Camera with Camera Link – User Manual
Address
Register Name
0x0528
Trg_Str_Del
0x052C
Str_One_En
0x0530
Str_One_Dur
0x0534
Str_One_Pos
0x0538
Str_Two_En
0x053C
Str_Two_Dur
0x0540
Str_Two_Pos
0x0544
Pls_Gen_Stp
0x0548
Pls_Gen_Wdt
July 6, 2018
Data
0x2 – enable Trigger Strobe
#1
0x3 – enable both Trigger
Strobe #1 and #2
Data
N/A
(31:2)
Data (23:0)
<value> –Strobe delay in
microseconds
Data (31:24)
N/A
Data (1:0)
0x0 – disable Strobe #1
0x1 – enable Strobe #1, each
frame
0x2 – enable Strobe #1, odd
frames only
0x3 – enable Strobe #1, even
frames only
Data (31:2)
N/A
Data (15:0)
<value> –Strobe #1 Pulse
width in microseconds
Data (31:16)
N/A
Data (23:0)
<value> –Strobe #1 Pulse
position in microseconds
up to one frame time
Data (31:24)
N/A
Data (1:0)
0x0 – disable Strobe #2
0x1 – enable Strobe #2 each
frame
0x2 – enable Strobe #2 odd
frames only
0x3 – enable Strobe #2 even
frames only
Data (31:2)
N/A
Data (15:0)
<value> –Strobe #2 Pulse
width in microseconds
Data (31:16)
N/A
Data (23:0)
<value> –Strobe #2 Pulse
position in microseconds
up to one frame time
Data (31:24)
N/A
Data (1:0)
0x0 – x1
0x1 – x10
0x2 – x100
0x3 – x1000
Data (31:2)
N/A
Data (23:0)
<value> –Sets Pulse width
in microseconds when
multiplied by granularity
setting
Data (31:24)
N/A
Page
62 of 64
Type
Usage
RW
Sets delay
between trigger
pulse and strobe
pulse.
RW
Sets Strobe 1
mode of
operation.
RW
Sets Strobe 1
duration in
microseconds.
RW
Sets Strobe 1
position in
microseconds.
RW
Sets Strobe #2
mode of
operation.
RW
Sets Strobe 2
duration in
microseconds.
RW
Sets Strobe 2
position in
microseconds.
RW
Sets pulse
generator main
timing resolution.
RW
Sets the value of
the pulse width in
microseconds
Rev 1.1