Imperx Cheetah C2020 User Manual page 17

Pregius cameras with camera link interface
Table of Contents

Advertisement

Cheetah Pregius Camera with Camera Link – User Manual
Figure 6: OUT1 LVTTL electrical connection.
D. Output OUT 2 – Solid state relay, optically isolated
Output OUT2 is an optically isolated switch. There is no pull-up voltage on either contact.
External pull-up voltage of up to 25 volts is required for operation. Output is not polarity
sensitive. AC or DC loads are possible. The voltage across OUT2 Contact 1 and OUT2
Contact 2
must not
exceed 25 volts and the current through the switch
must not
exceed
50 mA. On resistance is less than 5 Ohms.
Figure 7: Open drain logic driver.
Figure 8: Low side load driver.
July 6, 2018
Page
Rev 1.1
17 of 64

Advertisement