Vca - Event Triggered - Sony SNC-HMX70 User Manual

Hide thumbs Also See for SNC-HMX70:
Table of Contents

Advertisement

6
When finished, click Set to save the settings in the
device.
Holidays
Define holidays on which a profile should be active that
are different to the standard weekly schedule.
1
Click the Holidays tab. Any days that have already
been selected are shown in the table.
2
Click Add. A new window opens.
3
Select the desired date from the calendar. Select
several consecutive calendar days by holding down
the mouse button. These will later be displayed as a
single entry in the table.
4
Click OK to accept the selection. The window
closes.
5
Assign the individual holidays to the VCA profiles,
as described above.
Deleting Holidays
Delete defined holidays at any time:
1
Click Delete. A new window opens.
2
Click the date to delete.
3
Click OK. The item is deleted from the table and
the window closes.
4
The process must be repeated for deleting
additional days.

VCA - Event triggered

This configuration allows you to stipulate that the video
content analysis is only to be activated when triggered
by an event.
• In the VCA configuration drop-down list, select
Event triggered.
As long as no trigger is activated, the Silent VCA
configuration in which metadata is created is active; this
metadata facilitates searches of recordings, but does not
trigger an alarm.
The current alarm status is displayed for information
purposes.
Trigger
Select a physical alarm or a virtual alarm as a trigger. A
virtual alarm is created using software, with RCP+
commands or alarm scripts, for example.
Trigger active
Select the VCA configuration here that is to be enabled
via an active trigger. A green check mark to the right of
the list field indicates that the trigger is active.
Trigger inactive
Select the VCA configuration here that is to be activated
if the trigger is not active. A green check mark to the
right of the list field indicates that the trigger is inactive.
Delay [s]
Select the delay period for the reaction of the video
content analysis to trigger signals. The alarm is only
triggered after a set time interval in seconds has elapsed
and then only if the triggering condition still exists. If the
original condition has been restored before this time
interval elapses, the alarm is not triggered. A delay
period may be useful in avoiding false alarms or
frequent triggering. During the delay period, the Silent
VCA configuration is always enabled.
30