Checking the installation

Checking the configuration
Press the installation button
1
The
LED flashes yellow.
The colours of LEDs 1...8 indicate the
configuration of the temperature zones.
LEDs 1...8
Meaning
Off
No device installed
Red
Room setpoint generator/
sensor is installed
Yellow
Time program, setpoint adjuster and
room temperature sensor are installed
Green
Time program (room setpoint
temperature), e.g. evohome controller
Only if cooling was enabled
Press the installation button
2
The colours of LEDs 1...8 indicate
the assignment of the time programs
to the temperature zones.
LEDs 1...8
Meaning
Red
Time program for heating assigned
Yellow
Time program for heating/
cooling assigned
Green
Time program for cooling assigned
HCE80(R) / HCC80(R) Mounting and operation
.
again.
Test the radio communication
Sending test signals
!
The underfloor heating controller can
send a test signal to all the allocated radio
receivers in order to test the signal strength.
Keep the Mode and
1
simultaneously for at least 4 seconds.
The
The underfloor heating controller sends
a test signal every 5 seconds to the
allocated radio receivers. The zone
LEDs light up briefly during sending.
You can exit the test mode by pressing any button.
After 4 minutes the device changes
automatically to normal mode.
Receiving test signals
!
For information on sending a test
signal to the underfloor heating
controller read the instructions of the
corresponding device (radio test).
Send a test signal to the underfloor heating controller.
1
If a test signal is received, the
The zone LED of the corresponding zone
indicates the strength of the received signal
by flashing (1 = sufficient - 5 = strong).
buttons pressed
LED flashes green.
LED flashes green.
21