Section 9: Maintenance; Maintenance Schedule; Maintenance Considerations; Checking Flow And Water Levels - Pentair PR AQUA ROTOFILTER Installation And Operation Manual

Drum filter
Table of Contents

Advertisement

32

SECTION 9: MAINTENANCE

9.1 Maintenance Schedule

The Rotofilter requires maintenance to perform
efficiently and effectively. Frequent, scheduled
maintenance of the Rotofilter will reduce operating
costs and extend the life of the equipment.
Below is a basic maintenance schedule that should
be followed. Additional maintenance procedures
may be required or advantageous.
Daily Maintenance
Check flow and water levels ................................... 9.3
Inspect and clean spray bar nozzles ................... 10.1
Inspect mechanical parts ....................................... 9.4
Inspect screens ......................................................11.1
Inspect drum seal ................................................. 12.1
Remove deposits or fouling ..................................... —
Weekly Maintenance
Inspect and grease support wheels .................... 13.1
Clean float switch .................................................... 9.4
Clean solids trough .................................................. —
Adjust drive tension (belt/chain models) ..... 14.2/14.7
Monthly Maintenance
Wash screens ........................................................ 11.2
Inspect screen gasket seals ................................. 11.4
Inspect drive assembly ......................................... 14.1
Inspect support wheels for wear ......................... 13.1
Inspect oil bath levels (chain-drive models) ........ 14.6
Yearly Maintenance
Inspect / replace support wheels ........................ 13.4
Inspect / replace drum seal .................................. 12.1
PR Aqua Rotofilter
Drum Filter Installation and Operation Manual

9.2 Maintenance Considerations

Some maintenance procedures require the
Rotofilter to be dry. To perform these procedures,
Frame (RFF) models will need to have sumps that
can be drained or pumped. Molded (RFM and
Ultraviolet (RFUV) models have integrated drains
in their enclosures.
Some maintenance procedures are significantly
easier if they are performed at the same time. We
recommend that you replace screen panels, gasket
Manual Section
seals, and the drum seal at the same time.
These procedures maintain standard wear items
that should be replaced on a regular schedule.
Procedures contain common steps that need
only be performed once if the maintenance
procedures are performed in unison. In addition,
there is increased service access that facilitates
maintenance.
This manual provides the procedures as a
combined unit in Section 9.5, and also as
separate tasks.
Manual Section
If an issue occurs that is not covered by a
maintenance procedure listed in this manual,
please contact us.
consulting us limits our liability and may void
the Rotofilter warranty.
Manual Section

9.3 Checking Flow and Water Levels

Check flows at least once per day to ensure that
the water levels inside and outside the drum
remain within the acceptable range. Minimum
and maximum water levels are identified on the
specification documents.
Flow may need to be altered to maintain the
correct balance between water inside and
outside of the drum.
Manual Section