4.2.5 Operation When the Number of Determination Files Reaches the
Maximum Number of Generations
 Operation when the number of determination files reaches the maximum number of
generations
• The operation when the number of determination files reaches the maximum number of
generations varies depending on the log file settings.
File determination
condition
Setting of "When
max. generation"
Stop
Continue
"Logging File Settings" dialog box
4.2 Operation When Logging is Selected for Application
Operation
1) Determines a current file "specified file name (------current------).csv", gives the time
data of the oldest record, and renames it.
2) Creates a new current file "specified file name (------current------).csv".
1) Determines a current file "specified file name (------current------).csv", gives the time
data of the oldest record, and renames it.
2) Deletes the oldest file.
After deleting it, updates the data of the oldest file displayed in the system monitor area
(SM).
3) Creates a new current file "specified file name (------current------).csv".