Pump Installation; Plumbing; Pump Orientation; Rotation Of Pump Head - Whale Dry-Deck 20 SDP073R Installation Instructions Manual

Table of Contents

Advertisement

4

Pump Installation

1.1
Before mounting the pump refer to the
plumbing diagram opposite for maximum
pipe specification.
Mount the pump on a solid wall to prevent
vibration. Use a back board if this is not
possible.
Note: If mounted to a stud wall pump vibration
may cause noise through the resonance of the
wall. In these situations mount the pump on a
bracket off the floor. The pump may be mounted
horizontally on the floor if required.
Fix the pump in position through the feet with
the fixings provided.
1.2
Rotate the pump head if necessary to give a
straight run of pipe to the waste. Loosen the
clamping ring on the pump head and rotate
the head before retightening clamping ring.
Note: Do not remove the pump head.
Top Tip
To aid servicing the head of the pump must
be above the floor by at least 150 mm
(maximum height of 500 mm).

Plumbing

1.3
Push fit fittings are provided to connect the
pump to inlet and discharge pipework. Push
fit fittings are necessary to aid maintenance
and fault diagnosis. All pipework in and out
of the pump must be in 22 mm.
Ensure fittings are pushed home and locked.
1.1
1.2
1.3

Advertisement

Table of Contents
loading