Download Print this page
Ametek Gemco 1950-4 Manual
Ametek Gemco 1950-4 Manual

Ametek Gemco 1950-4 Manual

Micro-adjust rotating cam limit switches

Advertisement

Quick Links

SUGGESTED SET-UP PROCEDURE
The Gemco Micro-Adjust Cams may be adjusted either
before or after installation. The following procedure is
recommended for cam adjustment.
1. Mount the assembly and couple shaft driving member
with the shaft keyway aligned with the positioning arrow
located on the bearing end plate. The machine should be
in the start cycle position with all cams set at zero.
2. Turn cam adjustment disc to the desired setting,
observing the angular degree position markings on the
top of the cam block.
3. Follow the cam setting procedure as described inside
the cover of the enclosure.
Gemco
DESCRIPTION
The Gemco Rotating Cam Limit Switch has been
developed to meet all requirements for an industrial
multipurpose cam-actuated limit switch in applications
where precise repetitive sequential, automatic, or semi-
automatic operations are required in control circuitry.
When motion is expressed in shaft rotation, either
through a roller chain, gear train, or directly, the Gemco
Rotating Cam Limit Switch makes it possible to open or
close independent circuits at any desired angular position
of the input shaft. Any closed circuit or open circuit from
4° to 356° is obtainable without the use of special cams.
All cam settings can be adjusted at any angular position
of the cam shaft.
MAINTENANCE & INSTALLATION
Lifetime sealed ball bearings provide smooth
maintenance-free operation and allow mounting of the
Gemco Micro-Adjust Rotating Cam Limit Switch in any
position.
NO TOOLS NECESSARY!
TO ADJUST CAM SETTING
1
Section 1980S
TM

Advertisement

loading

Summary of Contents for Ametek Gemco 1950-4

  • Page 1 Section 1980S Gemco DESCRIPTION The Gemco Rotating Cam Limit Switch has been developed to meet all requirements for an industrial multipurpose cam-actuated limit switch in applications where precise repetitive sequential, automatic, or semi- automatic operations are required in control circuitry. When motion is expressed in shaft rotation, either through a roller chain, gear train, or directly, the Gemco Rotating Cam Limit Switch makes it possible to open or...
  • Page 2: Easy Setup Procedure

    EASY SETUP PROCEDURE MOUNTING OF UNIT Mount the assembly and couple the input shaft to the driving member, with the shaft keyway up and in line with the positioning arrow on the bearing end TYPICAL SETTINGS AT BEGINNING plate. The machine should be in the start cycle OF MACHINE CYCLE position.
  • Page 3: Application Note

    ELECTRICAL CONTACTS The welded silver cadmium oxide contacts provide the following advantages: (1) High electrical conductiv- ity, (2) Excellent resistance to sticking contacts, (3) Minimum electrical erosion. The presence of cadmium oxide gives high arc quenching characteristics of cadmium without a reduction of high conductivity of fine silver.
  • Page 4 Figure 1 NEMA 1 Style 4LLMM...
  • Page 5 Figure 2 NEMA 4 Style Figure 3 NEMA 12 Style...
  • Page 6 & ) " * Item not shown on drawing • It is recommended that snap switches be replaced after fifteen million operations. AMETEK Patriot Sensors 1080 N. Crooks Road Clawson, MI 48017 800-635-0289 248-435-0700 Fax 248-435-8120 Form 608 1980S.M1R...

This manual is also suitable for:

Gemco 1980 seriesGemco 1950-1