Mib (Manual Interface Board) Troubleshooting - Frymaster FilterQuick FQG30 Service Manual

Gas fryer
Table of Contents

Advertisement

1.15.2 MIB (Manual Interface Board) Troubleshooting

Problem
Auto filtration won't
start.
MIB display shows
something other than
an "A" or vat number.
No power present at
the MIB board
MIB will not clear
error.
MIB indicates
incorrect number of
vats.
Probable Causes
A. Filter pan out of position.
B. Oil level too low.
C. Ensure MIB board is not in
manual mode.
D. Ensure MIB cover is not
damaged and pressing against
buttons.
E. Filter relay has failed.
F. Filter motor thermal switch is
tripped.
An error has occurred and
displayed character indicates
error.
Transformer has failed in left
component box.
Error remains in non-volatile
memory.
A. Network is not terminated
correctly.
B. Wiring harnesses are loose or
damaged.
C. An AIF board issue.
D. Locator pin issue.
Corrective Action
A. Ensure filter pan is fully inserted into fryer.
If the MIB board displays a "P" the pan is
not fully engaged into the pan switch.
B. Ensure the oil level is above the top oil
level sensor.
C. Ensure MIB board is in "A" automatic
mode.
D. Remove and replace cover and see if
filtration will start.
E. Replace filter relay with part number 807-
4482 24VDC relay.
F. Press filter motor thermal switch.
See MIB display characters on page 1-34 for
explanation.
Check output on the left transformer in left
component box; should read 24VAC. If not
replace transformer.
Press and hold reset button in top right corner
of MIB board for five seconds. The drain,
return and manual/auto LEDS will illuminate
and the MIB will reset and clear any remaining
errors from memory. Allow 60 seconds to reset.
If an error still exists, then another issue exists.
A. Ensure the CAN bus system is terminated at
BOTH ENDS
controller connector J6 and on the ATO
board connector J9) with a resistor equipped
6-pin connector.
B. Unplug and reseat all wiring harnesses in
CAN system. Resistance between pins 2
and 3 on the CAN network connectors
should be 120 ohms.
C. Check software version numbers on all
FilterQuick™ controllers and ensure all
display an AIF version. If an AIF version is
missing, the AIF board may be missing
power or bad. Check pins 5 and on J4 and
J5 of the affected AIF board for proper
voltage.
D. The locator pin in J2 of the AIF board is
either loose or in the incorrect position. See
the charts on page 1-41 of this manual for
proper pin position.
1-31
(on the FilterQuick™

Hide quick links:

Advertisement

Table of Contents
loading