Probe Resistance Chart; Ato (Automatic Top-Off) Service Procedures; Ato (Automatic Top-Off Troubleshooting) - Frymaster FilterQuick FQG30 Service Manual

Gas fryer
Table of Contents

Advertisement

1.13

Probe Resistance Chart

For use with FilterQuick™ Series fryers manufactured with Minco Thermistor probes only.
F
OHMS
C
F
60
1059
16
130
65
1070
18
135
70
1080
21
140
75
1091
24
145
80
1101
27
150
85
1112
29
155
90
1122
32
160
95
1133
35
165
100
1143
38
170
105
1154
41
175
110
1164
43
180
115
1174
46
185
120
1185
49
190
125
1195
52
195

1.14 ATO (Automatic Top-off) Service Procedures

The automatic top-off system is activated when the oil level falls below a sensor in the front of the frypot. The
signal is sent to the ATO board to engage the return actuator to the frypot and turn on the ATO pump. The
pump draws oil from the JIB (Jug In Box) through the rear return manifold into the rear of the frypot. Once the
oil level has satisfied the sensor, the pump turns off and the actuator closes.
The ATO board is located inside the box, behind the JIB (see Figure 1). The
power for the ATO board is supplied from the transformer box. The power
passes through the transformer inside the ATO box to the board.
1.14.1 ATO (Automatic Top-Off) Troubleshooting
Problem
Fryer tops off cold. Incorrect setpoint.
No power to ATO board
One vat tops off but
other vats fail to top off.
Probe Resistance Chart
OHMS
C
F
1204
54
200
1216
57
205
1226
60
210
1237
63
215
1247
66
220
1258
68
225
1268
71
230
1278
74
235
1289
77
240
1299
79
245
1309
82
250
1320
85
255
1330
88
260
1340
91
265
Probable Causes
A. J5 connection unplugged
B. Fuse blown.
C. Transformer malfunction
A. Loose wire connection.
B. Actuator issue.
OHMS
C
F
OHMS
1350
93
270
1493
1361
96
275
1503
1371
99
280
1514
1381
102
285
1524
1391
104
290
1534
1402
107
295
1544
1412
110
300
1554
1422
113
305
1564
1432
116
310
1574
1442
118
315
1584
1453
121
320
1594
1463
124
325
1604
1473
127
330
1614
1483
129
335
1624
Ensure setpoint is correct.
A. Check to ensure J5 on front of ATO board
is fully locked into connector.
B. Ensure fuse located on right side of ATO
box is not blown.
C. Check that proper voltage is present at
transformer. See table in section 1.13.2.
A. Ensure all wiring harnesses are securely
connected to ATO board and solenoids.
B. Check return actuator to ensure actuator
is functional.
1-26
C
F
OHMS
132
340
1634
135
345
1644
138
350
1654
141
355
1664
143
360
1674
146
365
1684
149
370
1694
152
375
1704
154
380
1714
157
385
1724
160
390
1734
163
395
1744
166
400
1754
168
405
1764
Figure 1
Corrective Action
C
171
174
177
179
182
185
188
191
193
196
199
202
204
207

Hide quick links:

Advertisement

Table of Contents
loading