Specification
Altitude, non-operating
Shock, operating
Shock, non-operating
Vibration, operating
Vibration, non-operating
Vibration, relocation
Acoustics
Orientation and mounting:
Rack rails
Rack characteristics

Power cooling module

Specifications for the PCM are provided in the following table.
Table 39. 2U Power cooling module specifications
Specification
Dimensions (size)
Maximum output power
Voltage range
Frequency
Voltage range selection
Maximum inrush current
Measurement/description
Maximum operating temperature is de-rated by 5ºC above 2,133 meters (7,000 feet)
5U84 enclosures: -100 to 3,000 meters (-330 to 10,000 feet)
Maximum operating temperature is de-rated by 1ºC above 900 meters (3,000 feet)
-100 to 12,192 meters (-330 to 40,000 feet)
5.0 g, 10 ms, ½ sine pulses, Y-axis
2U enclosures: 30.0 g, 10 ms, ½ sine pulses
5U84 enclosures: 30.0 g, 10 ms, ½ sine pulses (Z-axis); 20.0 g, 10 ms, ½ sine pulses
(X- and Y-axes)
0.21 Grms 5 Hz to 500 Hz random
1.04 Grms 2 Hz to 200 Hz random
0.3 Grms 2 Hz to 200 Hz 0.4 decades per minute
Operating sound power
2U enclosures:< LWAd 6.6 Bels (re 1 pW) @ 23ºC
5U84 enclosures: < LWAd 8.0 Bels (re 1 pW) @ 23ºC
19" rack mount (2 EIA units; 5 EIA units)
To fit 800 mm depth racks compliant with the SSI server rack specification
Back pressure not exceeding 5Pa (~0.5 mm H20)
Measurement/description
84.3 mm high x 104.5 mm wide x 340.8 mm long:
• X-axis length: 104.5 mm (4.11 in)
• Y-axis length: 84.3 mm (3.32 in)
• Z-axis length: 340.8 mm (37.03)
580 W
100–200 VAC rated
50–60 Hz
Auto-ranging: 90–264 VAC, 47–63 Hz
20A
Technical specifications