Transporting Compactflash; Replacing A Ddic - Dell EMC ME4 Series Owner's Manual

Hide thumbs Also See for ME4 Series:
Table of Contents

Advertisement

Transporting CompactFlash

This action applies to single-controller enclosure configurations only. To prevent data loss in this environment, the CompactFlash must be
moved from the failed controller to the new controller module.
CAUTION:
Do not transport CompactFlash in a dual-controller environment. Doing so could cause data corruption.
Figure 61. CompactFlash memory card location
1
CompactFlash memory card (installed/removed)
Confirm that transporting CompactFlash is the appropriate action to take as discussed in the ME4 Series Storage System Deployment
Guide. Refer to
Figure 55. CompactFlash memory card location
Before you begin any procedure, see
1
Locate the CompactFlash memory card at the midplane-facing end of the failed controller module.
2
Grip the CompactFlash memory card and carefully pull it from the slot in the failed controller module.
3
Label the CompactFlash memory card as Data, and set it aside for safekeeping.
4
Locate the replacement controller module, and carefully remove its installed CompactFlash memory card.
a
Take care not to confuse this diskette with the one labeled Data.
b Insert this CompactFlash memory card into the failed controller module.
5
Align the CompactFlash memory card labeled Data for insertion into the replacement controller module—then insert it into the slot—
and push it forward until seated in place.

Replacing a DDIC

This procedure describes removal and installation of a Disk Drive in Carrier (DDIC). Illustrations in the DDIC replacement procedures show
drawer-centric views of the enclosure, and DDICs are properly aligned for insertion into the disk slots.
NOTE:
Remove a DDIC only if a replacement is available. Closing a drawer with one or more drives missing can potentially cause
cooling problems. See
1
Determine which drawer contains the disk to be replaced.
If the drive number is known, use the information contained in
from front
panel, which provides a single plan view of a drawer that is dual-indexed with top drawer (left integer) and bottom
drawer (right integer) slot numbering.
74
Module removal and replacement
ESD
precautions.
Populating
drawers.
2
IOM viewed from back (midplane-facing orientation)
when performing the step-procedure below.
Figure 20. 5U84 enclosure system - plan view of drawer accessed