APPENDIX B: JIB Preparation with Solid Shortening Option
1.
Open second or third door from the left of fryer and remove brace
in JIB cabinet.
2.
Attach alignment bracket to bottom of ATO box brace with provided
nuts. See Figure 1.
3.
Position melting unit in front of cabinet.
4.
Slide the melting unit tabs into the alignment guide slots. See Figure
2.
5.
With the melting unit inserted into the alignment guide bracket,
insert the inner oil reservoir pan into the tray. See Figure 3.
6.
Place the melting unit lid on the unit and slide the oil pickup tube
nipple into the female suction receptacle. See Figure 4.
7.
Use the provided screws to attach the melting unit to the bottom
of the interior rails on both sides using the existing holes. See
Figure 5.
8.
On the back side of the melter, attach the white two-pin
connectors and plug in the black connector to the outlet box
shown in Figure 6.
9.
Ensure the melting unit power switch is in the "ON" position. See
Figure 7.
Figure 3: Insert the inner oil
reservoir pan into the melting
unit.
Figure 6: Attach the two-pin white connectors and plug the black
connector into the utility box as shown. * Note the position of
the black connection may differ from photo.
 
Figure 4: Place the lid on the pan
and slide the oil pickup tube into the
female suction receptacle.
 
Orange button resets
system after a low oil
display.
  
B–1
Figure 1: Attach alignment bracket to bottom
of ATO box brace
Figure 2: Position the melter in the cabinet and
insert tabs into alignment guide slots.
Figure 5: Attach the melting unit to
the rails on both sides.
 
 
Figure 7: The assembled melting unit
is shown in position.
.
 
 
Melting
unit
power
switch.
 