11. Troubleshooting
If an error occurs, the courtesy LED will triple flash and an error code will be displayed on
the screen.
Error code
E1
E2
E3
E4
E5
E6
Not enough power supplied
E7
E8
E9
Lb
Description
Safety Beam Active
Safety Strip Advice
Door Imbalanced
Run Time Exceeded
Current Sensor
Collision
to the operator
Drive fault
DOSS fault
Low Battery
page 58
Possible Solution
Align Safety Beams, Check
connections, select two-wire or
four-wire safety beams with
corresponding jumper.
This is not applicable to SA operators.
Check door tension
(Door Service monitor).
Ensure that correct
door type is selected
(SE - Sectional, tu - Tip-up).
The door is too heavy for current force
setting, increase the force offset value.
Refer to
"8.3.3.1. Adjust Safety Offset Value"
Check door tension, guide rails
for any obstructions.
Check batteries and PSU.
Operator cannot run from PSU only.
Check fuse, motor connection and
drive circuit.
Check DOSS connection on PCB
Ensure batteries are
charged / connected.