353 – AL Open Load Cylinder B3
PV-Number:
Cause
Disruption fault in injector wiring
to cylinder B3.
354 – AL Open Load Cylinder B4
PV-Number:
Cause
Disruption fault in injector wiring
to cylinder B4.
355 – AL Open Load Cylinder B5
PV-Number:
Cause
Disruption fault in injector wiring
to cylinder B5.
356 – AL Open Load Cylinder B6
PV-Number:
Cause
Disruption fault in injector wiring
to cylinder B6.
356 – AL Open Load Cylinder B7
PV-Number:
Cause
Disruption fault in injector wiring
to cylinder B7.
84 | Troubleshooting | M015650/06E 2018-05
Corrective action
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
Corrective action
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
Corrective action
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
Corrective action
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.
Corrective action
1. Check wiring of affected injector (→ Page 160).
2. Check injector.
3. Replace injector (→ Page 112).
4. Contact Service.