DRAWER INSTALLATION
To remove and re-install individual drawers and drawer tracks, please refer to the
figure above for proper installation instructions.

MAINTENANCE

WARNING: DO NOT USE SHARP UTENSILS AND/OR OBJECTS.
WARNING: DO NOT USE STEEL PADS, WIRE BRUSHES, SCRAPERS, OR CHLORIDE
CLEANERS TO CLEAN YOUR STAINLESS STEEL.
CAUTION: DO NOT USE ABRASIVE CLEANING SOLVENTS, AND NEVER USE
HYDROCHLORIC ACID (MURIATIC ACID) ON STAINLESS STEEL.
WARNING: DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL
COMPONENTS MAY RESULT.
Unified Brands strongly suggests a preventive maintenance program which would
include the following monthly, weekly, and daily procedures:
If a failure of the equipment is a direct result of any of the Preventative Maintenance
guidelines being neglected, the repairs and parts replacements will not be covered
under warranty.
It is recommended that the customer contact the local Authorized Service Agent to
provide a quote to perform periodic Preventative Maintenance.
WEEKLY PM PROCEDURES
1. Clean all gaskets on a weekly if not daily basis with a solution of warm water
and a mild detergent to extend gasket life. Do not use bleach for cleaning
gaskets. Bleach will cause the gaskets to become brittle and not reach their
normal life expectancy.
2. Clean and disinfect rail drains with a solution of warm water and mild
detergent on a weekly basis. It is recommended to open and close the drain
valve as the hot water is flowing through to clean any debris from the internal
valve components.
MONTHLY PM PROCEDURES
1. Cleaning of all condenser coils on a monthly basis. Condenser coils are a
critical component in the life of the compressor and must remain clean to
assure proper air flow and heat transfer. Failure to maintain this heat transfer
will affect unit performance and eventually destroy the compressor. Clean the
condenser coils with coil cleaner and/or a vacuum, cleaner and brush. NOTE:
4
OM-8000 SERIES PREP TABLES
Brush coil in direction of fins, normally vertically as to not damage or restrict
air from passing through condenser.
2. Clean and disinfect drain lines and evaporator pan with a solution of warm
water and mild detergent on a monthly basis. Remove clear plastic drain line
from plastic tray of condensing unit and place pan under end of drain tube.
Discard waste water from pan when cleaning is complete. Re-insert plastic
drain tube into position on condensing unit.
3. Remove drawer tracks as per instructions on Drawer Installation guidelines.
Once drawers are removed wipe away any debris buildup from the drawer
tracks.
The roller bearings come lubricated from the factory. Excessive oils and or
water may remove the oils. It may be required to add lithium grease from time
to time on bearings that appear dry.
4. Inspect all silicone seams at interior of the rail and refrigerated base cabinet
on a monthly basis. Re-apply food grade silicone sealant as needed to any
seams where silicone has peeled away or cracked. Apply silicone to a clean
dry surface. Allow sufficient drying time to assure best adhesion of sealant.
RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE
FOLLOWING:
JOB
Soap, ammonia,
Routine cleaning
detergent Medallion
Arcal 20, Lac-O-Nu,
Fingerprints and smears
Ecoshine
Stubborn stains and
Cameo, Talc, Zud,
discoloration
First Impression
Greasy and fatty acids, blood,
Easy-Off, Degrease It,
burnt-on foods
Oven Aid
Any good commercial
Grease and Oil
detergent
Restoration/Preservation
Benefit, Super Sheen
Reference: Nickel Development Institute, Diversey Lever, Savin, Ecolab, NAFEM
Proper maintenance of equipment is the ultimate necessity in preventing costly
repairs. By evaluating each unit on a regular schedule, you can often catch
and repair minor problems before they completely disable the unit and become
burdensome on your entire operation.
For more information on preventive maintenance, consult your local service
company or CFESA member. Most repair companies offer this service at very
reasonable rates to allow you the time you need to run your business along with
the peace of mind that all your equipment will last throughout its expected life.
These services often offer guarantees as well as the flexibility in scheduling or
maintenance for your convenience. For a complete listing of current Unified Brands
ASA please visit www.unifiedbrands.net.
Unified Brands believes strongly in the products it manufactures and backs those
products with one of the best warranties in the industry. We believe with the
proper maintenance and use, you will realize a profitable return on your investment
and years of satisfied service.

REPLACEMENT PARTS

To order parts, contact your Authorized Service Agent. Supply the model
designation, serial number, part description, part number, quantity, and when
applicable, voltage and phase.
CONTACT US
If you have questions pertaining to the content in this manual, contact Unified
Brands at 888-994-7636 or tsrandell@unifiedbrands.net.
CLEANING AGENT
COMMENTS
Apply with a sponge or
cloth
Provides a barrier film
Rub in the direction of
the polish lines
Excellent removal on all
finishes
Apply with a sponge or
cloth
Good idea monthly

Hide quick links: