Randell FX-1A-290 Operator's Manual
Hide thumbs Also See for FX-1A-290:

Advertisement

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information on installation, operating,
maintenance, trouble shooting & replacement parts for:
FX SERIES:
FX-1-290
FX-1A-290
FX-1UC-290
FX-1RE-290
FX-1REA-290
• 2N1-Two Cooling Systems in one:
- Refrigerator (40ºF)
- Freezer (-5º to 0ºF)
- Or anywhere in between (-5º to 40ºF)
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER PP MNL1701, REV A (02/17)
FX-2WS-290
FX-2WSA-290
FX-2WSRE-290
FX-2WSREA-290
FX-2UCB-290
FX-3SS-290
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading

Summary of Contents for Randell FX-1A-290

  • Page 1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for: FX SERIES: FX-1-290 FX-2WS-290 FX-1A-290 FX-2WSA-290 FX-1UC-290 FX-2WSRE-290 FX-1RE-290 FX-2WSREA-290 FX-1REA-290 FX-2UCB-290 FX-3SS-290 • 2N1-Two Cooling Systems in one: - Refrigerator (40ºF)
  • Page 2: Important Operator Notices

    IMPORTANT - READ FIRST - IMPORTANT Congratulations on your recent purchase of Unified Brands food service equipment, and welcome to the growing family of satisfied Unified Brands customers. Our reputation for superior products is the result of consistent quality craftsmanship. From the earliest stages of product design to successive steps in fabrication and assembly, rigid standards of excellence are maintained by out staff of designers, engineers, and skilled employees.
  • Page 3: Table Of Contents

    Table of Contents Important Operator Notices ............page 2 Warranty Policies ................ page 4-6 Equipment Description ..............page 7 Installation ..................page 8 Operation ................page 9-10 Maintenance ................page 11 Troubleshooting ................page 12 Service ..................page 13 Parts List ................page 14-17 Electrical Schematic ..............
  • Page 4: Warranty Policies

    Warranty Policies Congratulations on your purchase of a Unified Brands Brand piece of equipment. Unified Brands believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit is the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence.
  • Page 5 Warranty Policies WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES Unified Brands will provide reimbursement of labor to an ASA for any customer that has an optional labor extension of our standard warranty. (Contracted rates do apply) Unified Brands offers both 1 and 2 year extensions. Labor extensions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchase.
  • Page 6: Warranty Policies

    Warranty Policies SANITATION & SAFETY REQUIREMENTS Product is designed to meet NSF sanitation and performance requirements, and UL safety requirements. Unified Brands is not responsible for specific local requirements unless made aware of them prior to bid process. Additional costs may apply. CANCELLATIONS Orders canceled prior to production scheduling entered into engineering/production and cancelled are subject to a cancellation charge (contact factory for details).
  • Page 7: Equipment Description

    Equipment Description FX-1-290 43.3” 28” 36” 0.88 1.65 1/4(1) 115/60/1 5-15P(1) FX-1A-290 43.3” 28” 14.7” 0.79 1/4(1) 115/60/1 5-15P(1) FX-1UC-290 27” 29.5” 33.2” 2.83 0.75 1.83 1/4(1) 115/60/1 5-15P(1) FX-1RE-290 35” 34.5” 16.3” 0.88 1.65 1/4(1) 115/60/1 5-15P(1) FX-1REA-290 35”...
  • Page 8: Installation

    Installation FAILURE TO FOLLOW INSTALLATION SELECTING A LOCATION FOR YOUR NEW UNIT GUIDELINES AND RECOMMENDATIONS MAY The following conditions should be considered when selecting a location for your unit: VOID THE WARRANTY ON YOUR UNIT. 1. Floor and Countertop Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit IT IS IMPORTANT THAT YOUR UNIT HAS plus the maximum product load weight.
  • Page 9: Operation

    Operation THE FX-1 SERIES UNIT IS DESIGNED TO Allow unit to operate for approximately two (2) hours before placing in food. OPERATE IN EITHER REFRIGERATOR OR FREEZER. FACTORY DEFAULT SETTING IS AMBIENT CONDITIONS FOR FREEZER MODE AND SET AT -3ºF. Unit is designed for normal operating temperatures are between 70-100°F.
  • Page 10: Operation

    Operation CHANGE FROM ºF /ºC : 1. Press the up/down buttons simultaneously for 5 seconds to access the menu. 2. Password is requested. Password is 000. 3. Press the bottom left button to OK the password. 4. Using the up/down buttons, navigate to the “diS” level. Press the bottom left button to OK the selection.
  • Page 11: Maintenance

    Maintenance Unified Brands strongly suggests a preventive maintenance program which would include DO NOT USE SHARP UTENSILS AND/OR the following Monthly procedures: OBJECTS. 1. Clean fan blades on the condensing unit and evaporator assembly. DO NOT USE STEEL PADS, WIRE BRUSHES, SCRAPERS, OR CHLORIDE CLEANERS TO 2.
  • Page 12: Troubleshooting

    Troubleshooting This unit is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are found at the end of this manual. SYMPTOM POSSIBLE CAUSE PROCEDURE No power to unit...
  • Page 13: Service

    Service This piece of equipment uses a R290 Refrigeration system. This equipment has been clearly marked on the serial tag the type of refrigerant that is being used. There is also a warning labels stating that the unit contains R290 refrigerant. R290 is safe to use as long as you follow these warning labels and some.
  • Page 14: Parts List

    Parts List ITEM PART NUMBER DESCRIPTION RF FAN0601 FAN. AXIAL, 127 X 38MM 120 CFM,115V CONDENSER FA BLT0349 BOLT, 6-32x1/2 T/H/P 18-8 SS 08BC PHILLIPS TRUSS SS FA NUT0312 RIVNUT, 6-32 THD RF CMP1604 COMPRESSOR, 3/8 HP, LO, 404, 115V, DANFOSS RF CMP1604SC COMPRESSOR START COMPONENTS RF FLT9902...
  • Page 15 Parts List ITEM PART NUMBER DESCRIPTION HD CST9801 2.5" SWIVEL CASTER (NO LOCK)--HD CST9801 HD CST9802 2.5" SWIVEL CASTER (WITH LOCK)--HD CST9802 RP PNL1702 PANEL BACK MACHINE COMP RP END1701 SIDE, EXTERIOR, S/S, RIGHT RP END1702 SIDE, EXTERIOR, S/S, LEFT RP BCK1701 BACK, EXTERIOR HD TRK1101_BASE...
  • Page 16 Parts List ITEM PART NUMBER DESCRIPTION RP PAN0705 INSULATED DRAWER TUB FOR FX-1, FX-1RE RP PAN0706 INSULATED DRAWER TUB FOR FX-1A, FX-REA RP PAN0801 INSULATED DRAWER TUB FOR FX-1UC RP GSK0604 GASKET, MAGNETIC, SLIDE SEAL, PF, 765 X 614mm RP DWR1603 DRAWER CARRAIGE ASSY W/FRONT, FX-1, FX-1RE RP DWR1504 DRAWER CARRIAGE ASSY W/FRONT, FX-1UC...
  • Page 17 Parts List ITEM PART NUMBER DESCRITPION RP DRP0602 EVAPORATOR DRAINING DRAIN PAN W/DEFROST ELEMENT PB ELB0313 ELBOW, 1/2" ID X 3/8" ID 90 CU CXC EL PAD1101 PAD, FLEXIBLE HEATING FOIL 6.9" X 15.75" 150W 120V RF COI0603 COIL, 1.00" X 7.00" X 15.7" STAGED FIN EVAPORATOR RP BRK0704 BRACKET FOR HI-LIMIT RF TRM0501...
  • Page 18: Electrical Schematic

    Electrical Schematic OM-FX SERIES...
  • Page 19: Labeling

    Labeling The following warning labels will be found on your equipment: INTERIOR EVAPORATOR COVER NEAR MACHINE COMPARTMENT AND NAMEPLATE OM-FX SERIES...
  • Page 20: Labeling

    Labeling EXTERIOR OF UNIT NEAR EXPOSED REFRIGERANT TUBING OM-FX SERIES...
  • Page 21: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-FX SERIES...
  • Page 24 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 unifiedbrands.net PART NUMBER PP MNL1701, REV A (02/17) © 2017 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.

Table of Contents