Advertisement

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information on installation, operating,
maintenance, trouble shooting & replacement parts for:
RANSPEC
REFRIGERATORS:
51000 Series
53000 Series
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER PP MNL1602, REV C (04/17)
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 51000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Randell 51000 Series

  • Page 1 This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for: RANSPEC REFRIGERATORS: 51000 Series 53000 Series THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
  • Page 2: Important Operator Notices

    IMPORTANT - READ FIRST - IMPORTANT Congratulations on your recent purchase of Unified Brands food service equipment, and welcome to the growing family of satisfied Unified Brands customers. Our reputation for superior products is the result of consistent quality craftsmanship. From the earliest stages of product design to successive steps in fabrication and assembly, rigid standards of excellence are maintained by out staff of designers, engineers, and skilled employees.
  • Page 3: Table Of Contents

    Table of Contents Important Operator Notices ............page 2 Warranty Policies ................ page 4-6 Equipment Description ..............page 7 Installation .................. page 8-9 Operation ..................page 10 Maintenance ................page 11-12 Troubleshooting ..............page 13-15 Parts List ................page 16-20 Electrical Schematic ..............
  • Page 4: Warranty Policies

    Warranty Policies Congratulations on your purchase of a Unified Brands Brand piece of equipment. Unified Brands believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit is the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence.
  • Page 5 Warranty Policies WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES Unified Brands will provide reimbursement of labor to an ASA for any customer that has an optional labor extension of our standard warranty. (Contracted rates do apply) Unified Brands offers both 1 and 2 year extensions. Labor extensions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchase.
  • Page 6: Installation

    Warranty Policies SANITATION & SAFETY REQUIREMENTS Product is designed to meet NSF sanitation and performance requirements, and UL safety requirements. Unified Brands is not responsible for specific local requirements unless made aware of them prior to bid process. Additional costs may apply. CANCELLATIONS Orders canceled prior to production scheduling entered into engineering/production and cancelled are subject to a cancellation charge (contact factory for details).
  • Page 7: Equipment Description

    Equipment Description SELF CONTAINED 51347 47” 33” 36” 134A (1)27” 5-15P 51362 62” 33” 36” 134A (2)24” 5-15P 51368 68” 33” 36” 134A (2)27” 5-15P 51386 86” 33” 36” 134A (3)24” 5-15P 51395 95” 33” 36” 134A (3)27” 5-15P 51362 shown with 51347PT-35 47”...
  • Page 8: Installation

    Installation FAILURE TO FOLLOW INSTALLATION SELECTING A LOCATION FOR YOUR NEW UNIT GUIDELINES AND RECOMMENDATIONS MAY The following conditions should be considered when selecting a location for your unit: VOID THE WARRANTY ON YOUR UNIT. 1. Floor and Countertop Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight.
  • Page 9 Installation IT IS IMPORTANT THAT A VOLTAGE READING ELECTRICAL SUPPLY BE MADE AT THE COMPRESSOR MOTOR Any wiring should be done by a qualified electrician in accordance with local electrical ELECTRICAL CONNECTIONS, WHILE THE UNIT codes. A properly wired and grounded outlet will assure proper operation. Please IS IN OPERATION TO VERIFY THE CORRECT consult the data tag attached to the compressor to ascertain the correct electrical VOLTAGE REQUIRED BY THE COMPRESSOR...
  • Page 10: Operation

    Operation Allow unit to operate for approximately two (2) hours before placing in food. AMBIENT CONDITIONS This unit is designed for indoor operation in a room with maximum ambient 86°F and 55% relative humidity or less. It should never be used outside or located in direct sunlight. Unified Brands has attempted to preset the temperature control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food type and your type of operation, you may need to alter this temperature...
  • Page 11: Maintenance

    Maintenance Unified Brands strongly suggests a preventive maintenance program which would include DO NOT USE SHARP UTENSILS AND/OR the following Monthly procedures: OBJECTS. 1. Cleaning of all condenser coils. Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer. BRUSH COIL IN DIRECTION OF FINS, Failure to maintain this heat transfer will affect unit performance and eventually destroy NORMALLY VERTICALLY AS TO NOT DAMAGE...
  • Page 12: Maintenance

    Maintenance To remove and re-install drawer tracks, please refer to figure below for instructions. Proper maintenance of equipment is the ultimate necessity in preventing costly repairs. By evaluating each unit on a regular schedule, you can often catch and repair minor problems before they completely disable the unit and become burdensome on your entire operation.
  • Page 13: Troubleshooting

    Troubleshooting This unit is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are found at the end of this manual. SYMPTOM POSSIBLE CAUSE PROCEDURE 1.
  • Page 14 Troubleshooting CLEANING CONDENSOR COIL An accumulation of dirt and dust prevents the condenser coil from removing, making your unit cool poorly, run constantly, or even stop completely if the compressor overheats. Clean coil using a vacuum cleaner with wand attachment. If the coil is greasy, wash it with a solution of warm water the mild detergent using a bristle brush.
  • Page 15 Troubleshooting SERVICING THE COMPRESSOR The compressor is part of the sealed refrigeration system and should be replaced by a professional service technician. You can, however, test the compressor and certain components. Prior to testing, unplug the unit and remove the access cover to the mechanical housing.
  • Page 16: Parts List

    CALL UNIFIED BRANDS SERVICE & PARTS Parts List HOTLINE FOR REPLACEMENT PARTS 888-994-7636 ITEM DESCRIPTION PART NUMBER 51347 51347PT 51362 51368 51368PT 51386 51395 DOOR HINGE – NON-SELF CLOSING RP HNG9900 DOOR GASKET – 18.5 X 22.5 IN GSK1006 DOOR GASKET – 21.75 X 22.5 IN GSK1010 DOOR GASKET –...
  • Page 17 CALL UNIFIED BRANDS SERVICE & PARTS Parts List HOTLINE FOR REPLACEMENT PARTS 888-994-7636 OM-51000 & 53000 SERIES...
  • Page 18 CALL UNIFIED BRANDS SERVICE & PARTS Parts List HOTLINE FOR REPLACEMENT PARTS 888-994-7636 ITEM DESCRIPTION PART NUMBER 51347 51347PT 51362 51368 51368PT 51386 51395 CASTER W/BREAK – 4” (OPTION) HD CST040HD CASTER W/BREAK – 6” (OPTION) HD CST060 CASTER W/O BREAK – 4” (OPTION) HD CST041HD CASTER W/O BREAK –...
  • Page 19 CALL UNIFIED BRANDS SERVICE & PARTS Parts List HOTLINE FOR REPLACEMENT PARTS 888-994-7636 ITEM DESCRIPTION PART NUMBER 51347 51347PT 51362 51368 51368PT 51386 51395 HANGING THERMOMETER – 4” HD THR100 SHELF SUPPORT – BETWEEN DOORS RP BRK0108 SHELF SUPPORT – FRONT & BACK RP BRK0107 SHELF SUPPORT –...
  • Page 20 CALL UNIFIED BRANDS SERVICE & PARTS Parts List HOTLINE FOR REPLACEMENT PARTS 888-994-7636 ITEM DESCRIPTION PART NUMBER 51347 51347PT 51362 51368 51368PT 51386 51395 EVAPORATOR DRIP PAN – PLASTIC RD DRP107 EVAPORATOR COIL RF COI107 EVAPORATOR COIL DRAIN TUBE PL TBG075 EVAPORATOR COIL HOUSING –...
  • Page 21: Electrical Schematic

    ALL MODELS: Electrical Schematic EXCLUDING 51386, 51395 & PASS THRU UNITS OM-51000 & 53000 SERIES...
  • Page 22 Electrical Schematic MODELS: 51386 & 51395 OM-51000 & 53000 SERIES...
  • Page 23 Electrical Schematic ALL PASS THRU MODELS: 51347PT-35 / -52 & 51368PT-35 / -52 OM-51000 & 53000 SERIES...
  • Page 24: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-51000 & 53000 SERIES...
  • Page 25 OM-51000 & 53000 SERIES...
  • Page 28 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 unifiedbrands.net PART NUMBER PP MNL1602, REV C (04/17) © 2017 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.

This manual is also suitable for:

53000 series

Table of Contents