Mounting Fans - Siemens SIMOTICS GP series Operating Instructions Manual

Low-voltage motors. standard motors sh 63 ... 355. 1la5/7/9, 1le1, 1fp1/3, 1lg4/6, 1lp5, 1pc3/4, 1pp5/6.
Table of Contents

Advertisement

Maintenance
9.3 Corrective maintenance
Shaft height 180 ... 200
1. Carefully release the first snap opening of the cover.
2. For machines with type construction B3, select the snap opening in the area of the
machine mounting feet.
3. Insert the lever at the edge of the cover close to the lug.
4. Carefully release 2 other snap openings together and then withdraw the cover.
5. Take care to not damage the catch mechanism. Order the appropriate new parts if
damaged.
Canopy
Canopies with spacer bolts or with screwed mounting brackets
Forcibly removing or separating can destroy the distance bolts, the connecting elements of
the mounting bracket or the fan cover.
● Release the fixing screw on the outer surface of the canopy.
● Under no circumstances remove the spacer bolts or the mounting bracket – or forcibly
separate them from one another or the cover.
Canopies with welded support brackets
● Release the fixing screws at the contact location (canopy foot - riveting nut) at the outer
surface of the cover mesh.
9.3.3.2

Mounting fans

● Take care not to damage the snapping mechanisms on fans that are equipped with these.
● To ensure this, the fans should be heated to a temperature of approximately 50 °C
around the area of the hub.
● If any damage is caused, request new parts.