Maintenance
9.2 Inspection and maintenance
Measures, intervals and deadlines
Measures after operating period intervals or deadlines have elapsed:
Operating situations and characteristics can vary widely. For this reason, only general
maintenance intervals are specified here. Maintenance intervals should therefore be
scheduled to suit the local conditions (dirt, starting frequency, load, etc.).
Table 9- 3
Measures
Initial inspection
Relubrication (optional)
Clean
Main inspection
Drain condensate
9.2.7

Re-greasing

For machines with regreasing system, relubrication intervals, grease quantity and grease
grade are provided on the lubricant plate. Additional data can be taken from the main
machine rating plate.
Grade of grease for standard motors (IP55) UNIREX N3 - ESSO.
Note
It is not permissible to mix different types of grease.
Prolonged storage periods reduce the useful lifetime of the bearing grease. Check the
condition of the grease if the equipment has been in storage for more than 12 months. If the
grease is found to have lost oil content or to be contaminated, the machine must be
immediately relubricated before commissioning. For information on permanently-greased
bearings, please refer to the section titled Rolling bearings (Page 106).
Procedure
To relubricate the rolling bearings, proceed as follows:
1. Clean the grease nipples at the drive end and non-drive end.
2. Press-in the specified grease and amount of grease according to the data stamped on the
lubrication plate.
– Please observe the information on the rating and lubricant plates.
– Regreasing should be carried out when the motor is running (max. 3600 rpm).
102
Operating period intervals
Operating period intervals
After 500 operating hours
See the lubricant plate
Depending on the degree of pollution
Approximately every 16000 operating
hours
Depending on the climatic conditions
Intervals
After 1/2 year at the latest
After two years at the latest
Standard motors SH 63 ... 355
Operating Instructions, 12/2018, A5E38483075A