(6) Reactors
For LGH-150RVXT-E and LGH-200RVXT-E
1 Remove the control cover. → See (3) 1.
2 Check that LED4 on the control circuit board is OFF.
→ See (2) 2.
3 Unscrew the screws (six PTT screws 4×8, indicated
by ), and remove the control base from the main
unit.
4 Unscrew the screws (three PT screws 4×8, indicated
by ), and remove the sub control base.
5 Unscrew the screws (two PT screws 4×8 for each, indi-
cated by ) to remove the reactors.
Note: LGH-150/200RVXT-E Lossnay has four reactors.
Assembly precaution
Number indications are attached on the lead wires.
When replacing the reactors, install them to the correct
position, and reconnect the lead wires according to the
numbers shown in the picture.
Sub control base
Control base
1
2
3
4
Reactor (Yellow)
─ 42 ─
5
6
7
8
Reactor (White)