Mira Orbis Installation And User Manual page 27

Thermostatic electric shower
Hide thumbs Also See for Orbis:
Table of Contents

Advertisement

Symptom
LCD
Back
Light
Low or no flow
ON
rate
ON
No information
ON
shown on LCD
display
Operation of
ON
temperature
control has
little or no
ON
effect on water
temperature.
ON
OFF
No change in
ON
temperature
between Low/
Medium/High
ON
setting.
OFF
OFF
Water will not
ON
turn off.
ON
Low Flow
Heater Setting
Light
Low/Medium/
High
OFF
Any
OFF
Any
OFF
Any
ON
Medium/High
OFF
Medium/High
OFF
Medium/High
OFF
ON
Any
OFF
Any
OFF
OFF
OFF
Any
ON
Any
27
Probable Cause
Handset blocked.
Heater tank
excessively scaled.
Faulty Control
PCB.
Handset or inlet
filter blocked.
Thermostatic valve
faulty.
Heater tank failure.
Relay PCB failure.
Insufficient mains
water pressure.
Possible failure of
thermostatic valve
or heater tank.
Control PCB
failure.
Thermal Trip failed.
Inlet valve,
solenoid, stop
switch, relay PCB
or Control PCB
faulty.
Supply pressure
below 20 kPa
(0.2 bar).
Probable Remedy
Remove and clean.
Replace. In hard
water areas
consider the use of
a water softener.
Replace Control
PCB.
Remove and clean.
Replace.
Replace.
Replace Relay PCB
assembly.
Contact local water
company.
Check the continuity
of the heater tank
and replace parts as
necessary.
Replace Control
PCB assembly.
Replace thermal
trip or check the
continuity of the
heater tank and
replace parts as
necessary.
Replace as
necessary.
Contact local water
company. Check
mains water static
pressure.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents