Feed cable into Case. Fit Earth sleeve
(not supplied) and strip insulation.
Do not twist cable cores.
Firmly connect the conductors. Do not
exert strain on the terminal block.
Before refitting the cover, pull the plastic
tab off the battery to activate it.
Refit the Service Tunnel.
Connect the multi-connector to the
socket on the PCB.
Refit the Cover. Make sure that it fits
correctly. Do not overtighten screws.
Do not use alternative screws to secure
the Cover. This can cause internal
damage to the appliance. Do not seal
around the back of appliance.
Install the shower fittings in accordance
with the manufacturer's instructions.
Service Tunnel
14
Important! Make sure
that the inlet earth wire is
routed as shown. Failure
to do so may cause
product malfunction.
L = BROWN
E = GREEN/YELLOW
N = BLUE
Cover Retaining
Screw
Cover