Installation and Configuration

ATTENTION:
• Installation and service must be performed by experienced personnel.
• L'installation et l'entretien doivent être effectués par du personnel expérimenté.
Step 1 — Get Ready
Familiarize yourself with the features of the transmitter and receiver (see
1.
Features
on page 4).
Download and install the latest version of the following:
2.
PCS Product Configuration Software — for detecting and configuring the AV settings for the transmitter-receiver pair
Toolbelt software — for discovering the HCR 102 receiver and other control products on the network, for managing
core settings, and for upgrading firmware if the need arises
Global Configurator
modes include a link to the Toolbelt software.
IP Link
 Pro device drivers — for use with GC, to make control of other AV devices possible
®
All are avail able from
Obtain network information for the unit from the network administrator. You will need the following details for each HCR 102
3.
receiver and for any other Extron Pro control product that is part of the system:
DHCP setting (on or off)
Device (HCR 102) LAN IP address
Write down the MAC address of each HCR 102 (see figure 4,
4.
Obtain model names and setup information for devices the HCR 102 will control.
5.
Step 2 — Mount the Half Rack Units, Prepare the Installation Site for the HCT 102 D
Turn off or disconnect all equipment power sources and mount the transmitter and receiver as required
Mounting the HCT 103 and HCR 102
The HCT 103 transmitter and HCR 102 receiver ship with furniture mounting brackets attached for mounting to furniture or a wall.
Figure 6.
Mounting the Transmitter (Left) and the Receiver (Right)
Each transmitter or receiver is one inch high, one half rack wide, and can be rack mounted. The product page on
www.extron.com
includes links to recommended optional rack shelves or rack mounting kits. Alternatively, you can remove the
pre-installed furniture mounting brackets and attach four rubber feet at the corners of each unit and place it on a table or desk.
Observe local and UL safety guidelines for mounting devices to equipment racks. See the HC 400 Series User Guide for UL rack
mounting guidelines.
(GC) software — for setting up and configuring the control system. GC Professional and GC Plus
®
www.extron.com
(see
Locating Software, Firmware, and Driver Files on the Extron Website
Front Panel Features
Subnet mask
Gateway IP address
O
on the previous page) or other IP Link Pro device to be used.
NOTE:
Rear and Side Panel
and
on page 18).
Username
Passwords
The receiver is designed so that its
vents face away from the wall or furniture
when mounted in order to achieve
optimal air circulation and cooling.