Danfoss MCA 124 Operating Instructions Manual page 50

Table of Contents

Advertisement

Troubleshooting
Bit (Hex)
Unit
Warning word
diagnose
(16-92 Warning Word)
bit
00000001
112
Brake check
00000002
113
Power card over
temperature
00000004
114
Earth fault
00000008
115
Control card
00000010
116
Control word timeout
00000020
117
Over current
00000040
118
Torque limit
00000080
119
Motor thermistor over
temp.
00000100
104
Motor ETR over
temperature
00000200
105
Inverter overloaded
00000400
106
DC link under voltage
00000800
107
DC link over voltage
00001000
108
DC link voltage low
00002000
109
DC link voltage high
00004000
110
Mains phase loss
00008000
111
No motor
00010000
96
Live zero error
00020000
97
10 V low
00040000
98
Brake overload
00080000
99
Brake resistor short circuit
00100000
100
Brake chopper fault
00200000
101
Speed limit
00400000
102
Fieldbus comm. fault
00800000
103
24 V supply fault
01000000
88
Mains failure
02000000
89
Current limit
04000000
90
Low temperature
08000000
91
Voltage limit
10000000
92
Encoder loss
20000000
93
Output frequency limit
40000000
94
Unused
80000000
95
Warning word 2 (ext. stat.
word)
Table 10.17
MCA 124 EtherCAT Operating Instruction
Alarm no.
Bit (Hex)
28
00000001
29
00000002
00000004
14
00000008
65
00000010
18
00000020
13
00000040
12
00000080
11
00000100
00000200
10
00000400
00000800
9
00001000
8
00002000
7
00004000
6
00008000
5
Table 10.18
4
3
Bit (Hex)
2
00000001
1
00000002
26
00000004
25
00000008
27
00000010
49
00000020
34
00000040
47
00000080
36
00000100
59
00000200
66
00000400
64
00000800
61
00001000
62
00002000
-
00004000
-
00008000
Table 10.19
NOTE
16-84 Comm. Option STW is not part of extended diagnosis.
®
MG92A302 - VLT
is a registered Danfoss trademark
Unit
PROFIBUS warning word (9-53 Profibus
diagnose
Warning Word)
bit
160
Connection with DP-master is not ok
161
Unused
162
FDL (Fieldbus Data link Layer) is not ok
163
Clear data command received
164
Actual value is not updated
165
Baudrate search
166
PROFIBUS ASIC is not transmitting
167
Initialising of PROFIBUS is not ok
152
Drive is tripped
153
Internal CAN error
154
Wrong configuration data from PLC
155
Wrong ID sent by PLC
156
Internal error occurred
157
Not configured
158
Timeout active
159
Warning 34 active
Comm. option STW (16-84 Comm. Option STW)
parameterization ok
configuration ok
clearmode active
baudrate search
waiting for parameterization
waiting for configuration
in data exchange
not used
not used
not used
not used
MCL2/1 connected
MCL2/2 connected
MCL2/3 connected
data transport active
not used
10
10
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents