............20 Telematic setting of the immobilizer Programming using a tag ..............21 Entry in the programming mode using the service code for immobilizer i95 LUX ........................22 Entry in the programming mode using the service code for immobilizer i95, i95 ECO......................... 24 Parameter programming table ................
LUX, i95, i95 ECO installation manual Table of possible indications Specifications Blocking Parameter Indication module module Sound indica- Event Tag (LED) Notes Frequency range of tion 2405...2480 control radio signals, MHz Warning of upcoming intermittent Take action to stop...
General mounting requirements Placement recommendations • The StarLine i95 LUX, i95, i95 ECO immobilizer is intended for The blocking module should be placed hidden in areas, inaccessible installation on cars and motor vehicles with the onboard supply for inspection without partial disassembly of the body elements, voltage of 12 V.
LUX, i95, i95 ECO installation manual Immobilizer connection INCORRECT Power connection The GND wire of the blocking module should be connected to the car body or a conductor reliably connected with the body. This wire should be connected the first during mounting.
LUX, i95, i95 ECO installation manual Hood lock outputs connection Relay contacts current should be not more than 10 A for a long time and not more than 20 A with duration up to 1 minute (in case of circuit The UNLOCK and LOCK outputs are intended for control of the hood switching without the inductive component in the load).
LUX, i95, i95 ECO installation manual “Status” output connection (i95 LUX) The INPUT wire should be connected to the corresponding limit switch, this will allow the system to trace the door’s or hood’s state. If the door or hood is open, the lock will not lock. Ground (–) should be The “status”...
• “Status” output on the touch sensor (over 3 seconds) or at tag moving-away. The output operation algorithm fully matches the description given in “Status output connection”. The status output for immobilizer i95 ECO operates only with the ignition switched on.
ATTENTION! When the system is set to the programming mode using the service code, the option of unlocking code change will be unavailable. For quick and convenient setting of immobilizer parameters on a computer, download the special application “StarLine Master” from www.starline.ru the website...
LUX, i95, i95 ECO installation manual Entry in the programming mode using the service Switchover to the programming mode. Example of service code entry – 9567. code for immobilizer i95 LUX 1) Switch on the ignition. Press and hold the indication module button for at least 3 seconds –...
Page 13
Entry in the programming mode using the service Switchover to the programming mode. Example of service code entry – 9567. code for immobilizer i95, i95 ECO 1) Remove all tags from the immobilizer coverage range (or remove all batteries from them). 2) Switch on the ignition. Wait for a sound signal and switch off the ignition.
LUX, i95, i95 ECO installation manual Parameter programming table 3) Press the tag button three times while the LED is illuminated red. After the end of illumination a series of red flashes will follow, the number The reference table given below can be used during immobilizer of which will correspond to the number of programming.
Page 15
Hand touch sensor *Only for immobilizer i95 LUX, i95. On (default) Allows engine blocking after driving start **The status output for immobilizer i95 ECO Stop lights operates only with the ignition switched on Marker lights “Hands free” mode (page 32)
LUX, i95, i95 ECO installation manual Testing of coverage range Parameter Value Description Note Allows and prohibits light indication of tag Common light indication (page 38) detection and warning about upcoming This option allows to check stability of communication between the On (default) blocking.
• Negative input of the touch sensor (i95 LUX, i95). In the “Hands free” mode when the tag is present in the blocking module Distance and stability of tag communication with the blocking...
LUX, i95, i95 ECO installation manual Engine blocking setting Delay before blocking activation in the Anti hijack mode The interval between driving start and blocking activation in the Anti Driving start sensor sensitivity hijack mode (40, 60 or 120 seconds) is selected based on the time necessary for malefactor’s departure from the robbery site.
LUX, i95, i95 ECO installation manual Registration of new devices Light and sound alarm setting Common sound indication To prevent unauthorized tag registration, entry in the device registration mode is possible only after entry of the unlocking code. For...
Page 21
The manufacturer reserves the right to change the design and elements without prior notification Manufacturer: Limited Liability Company “Scientific and Production Association “StarLine” (LLC “SPA “StarLine”) 194044, Russia, Saint Petersburg, 9 Komissara Smirnova Str.
Need help?
Do you have a question about the i95 and is the answer not in the manual?