Connection for RTD inputs:
Connection for mV/thermocouple inputs:
Connection for voltage outputs:
Connection for current outputs:
Phone: 425/745-3229 • Fax: 425/745-3429 • Email: maple@maplesystems.com • www.maplesystems.com
Doc. No. 1011-0715
Configuration:
Use MAPware-7000 to assign input (XW) output (YW) and
configuration (MW) memory addresses to the module.
These addresses are created according to the slot location of
the module, where nn refers to the slot number (ex. 01... 05):
Register
Description
XWnn00
Input Channel 1 Data
XWnn02
Input Channel 2 Data
XWnn04
Input Channel 3 Data
XWnn06
Input Channel 4 Data
YWnn00
Output Channel 1 Data
YWnn01
Output Channel 2 Data
MWnn00
Input Channel 1 Config. Reg.
MWnn01
Input Channel 2 Config. Reg.
MWnn02
Input Channel 3 Config. Reg.
MWnn03
Input Channel 4 Config. Reg.
MWnn04
Output Channel 1 Config. Reg.
MWnn05
Output Channel 2 Config. Reg.
MWnn10
Analog Input Error Reg.
Reference the table below when configuring each Input
Configuration Register (MWnn00 – MWnn03)
Input Channel Signal Type
Value
Voltage 0 to 10V
Voltage, 0 to 5V
Voltage, -10 to +10
18
Voltage, 0 to 50 mV
Voltage, 0 to 100mV
Current, 4 to 20mA
Current, 0 to 20mA
RTD and Thermocouple
For °C
RTD, PT100, alpha1
1
RTD, PT100, alpha2
1
RTD, PT1000
Thermocouple Type J
14
2
Thermocouple Type K
15
2
1. alpha1= 0.00385 Ω/Ω/°C, alpha2=0.003926 Ω/Ω/°C
2. 15-minute module warm-up time recommended
Reference the table below when configuring each
Output Configuration Register (MWnn04 – MWnn05)
Output Channel Signal
Value
Type
Voltage, 0 to 10V
2
Voltage, 0 to 5V
1
Current, 4 to 20mA
5
Current, 0 to 20mA
6
Page 2 of 2
Additional Resources:
Access
Read Only
Detailed instructions on the operation and installation of the
HMC7000 Series are available in the HMC7000 Programming
Read Only
Manual that is included with the MAPware-7000 configuration
Read Only
software. MAPware-7000 also includes help files, which
Read Only
provide detailed information on using the configuration
Read/Write
software.
Read/Write
Read/Write
Read/Write
Read/Write
WARNING: DO NOT REMOVE OR REPLACE WHILE CIRCUIT
Read/Write
IS LIVE UNLESS THE AREA IS KNOWN TO BE FREE OF
Read/Write
IGNITIBLE CONCENTRATIONS OF FLAMMABLE SUBSTANCES.
Read/Write
This equipment is suitable for use in Class I, Division 2, Groups
Read/Write
A, B, C and D or non-hazardous locations only.
WARNING – EXPLOSION HAZARD – Do not disconnect
equipment unless power has been removed or the area is
known to be non-hazardous.
Value
1
-
WARNING – EXPLOSION HAZARD - Substitution of
6
-
components may impair suitability for Class I, Division 2.
-
5
-
4
-
It is recommended that the user periodically inspect the sealed
2
-
devices used, check for any degradation of properties, and
3
-
replace as necessary.
For °F
7
19
8
20
For Technical Support:
9
21
Please contact Maple Systems if you have any questions
26
regarding this product. We ask that you provide us with the
27
unit serial number and firmware revision number written on
the product label of the unit.
Maple Systems Inc.
808 134
th
Everett, WA 98204
Tel: 425-745-3229
Fax: 425-745-3429
Email: support@maplesystems.com
Website: www.maplesystems.com
Model HMC7-MIO-08
St. SW, STE 120
Rev. 05, 05/18/2016
Need help?
Do you have a question about the HMC7-MIO-08 and is the answer not in the manual?