Password Protection And User Functions - WAGNER TwinControl 5-60 ABS Translation Of The Original Operating Manual

Electronic mixing ratio controller for 2k paints
Table of Contents

Advertisement

EDITION 04/2010
OPERATING MANUAL
6.9

PASSWORD PROTECTION AND USER FUNCTIONS

Level 0 Painter
Function:
Start, Stop, fl ush, (option circulate)
Press "+" and "-" simultaneously, SET, Password Level 1, SET
Level 1 Painter with control job
Function:
Start, Stop, fl ush, (option circulate)
"+" "-" ,
View only:
(P0=1)
Job quantity, total quantity, calibration value, pot life time, latest alarm,
mixed material in hose, fi ll quantity A, B, fl ush quantity A, B
Press "+" and "-" simultaneously, SET, Password Level 2, SET
Level 2 Boss
Function:
Start, Stop, fl ush, (option circulate)
View and change:
Job quantity, total quantity, mixed material in hose, fi ll quantity A, B, fl ush
quantity A, B, mixing ratio, pot life time.
View only: calibration value, alarms
Press "+" and "-" simultaneously, SET, Password Level 3, SET
Level 3 Service
Function:
Start, Stop, fl ush, (option circulate)
View and change:
Job quantity, total quantity, mixed material in hose, fi ll quantity A, B, fi ll
quantity A, B, calibration value, alarms, mixing ratio, pot life time.
View and change: parameter P0 to P99.
Exceptions:
The parameters P13, P14, P15, P17, P18 and P19 can be seen only.
The passwords, which are set by Wagner with the distribution of the equipment, are not
contained for safety reasons in the manual. The valid passwords are communicated to the
customer separately.
PART NO. DOC393831
TwinControl
"+" "-"
(P0=0)
"+" "-" ,
(P0=0)
"+" "-" ,
(P0=1)
"+" "-" ,
"+" "-" ,
.
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents