START-UP AND OPERATION

6.1

GENERAL RULES FOR USE OF THE SPRAY SYSTEM

Observe general safety instructions in chapter 2.
The operating documents provided by Wagner for the pneumatic pumps and other system
components should be read through carefully. The appropriate operating manual are avail-
able on the Wagner CD as pdf fi le.
Also observe the operating instructions for the components mounted on site.
Constant supply pressures!
Poor coating results
The supply pressure of the component B must be adjust to a higher value (appr. 10%)
than that the component A.
The supplying pressure should be constant.
SIHI_0056_GB
High-pressure spray jet!
Danger to life from injecting paint or solvent
SIHI_0059_GB
Gas mixtures can explode if there is an incompletely filled
unit!
Danger to life from flying parts
SIHI_0058_GB
PART NO. DOC393831
CAUTION
Never reach into the spray jet.
Never point the spray gun at peole.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high-pressure parts, instead relieve the
pressure from them and replace.
Wear the appropriate protective clothing, gloves, eyewear, and
respirator.
Ensure that the unit is always completely filled with cleaning
agent or working medium.
Do not spray the unit empty after cleaning.