6.3 Storage

Storage of packages
7

Installation and commissioning

7.1 Safety instructions for installation and commissioning

METIS Vision MV05 / MV09 Rugged Thermovision Camera
Only store packages under the following conditions:
Do not store outdoors.
Store in a dry and dust-free location.
Do not expose packages to aggressive media.
Protect the packages from direct sunlight.
Avoid mechanical vibration.
Storage temperature: -20 – 53°C
Relative humidity: Max. 60%.
NOTICE!
Damage to the camera due to excessive
temperatures!
-
Maintain sufficient distance to the measurement
object and check temperature at the place of action
prior to mounting and after commissioning
Chapter 3.5 "Optical Data" on page 11).
(
For temperatures in excess of 45°C use a cooling plate or
a cooling jacket for shielding (
on page 17).
Measurement inaccuracies due to vibrations,
disturbing objects, and intermediate media!
If the Thermovision Camera is exposed to high vibrations
or if disturbing objects or intermediate media (e.g.
windows, smoke, dust, steam) are located between the
Thermovision Camera and measurement object incorrect
measurements can result.
Comply with the mounting instructions (
"Mechanical installation" on page 20).
Chapter 5.3 'Accessories'
Chapter 7.2
19