M10
LEGEND
A = Hot water inlet (~ 50°C)
B = Cold water inlet (~ 15°C)
C = Variable shutter (max 7 l/min)
M1 = Duo-Rinse pump
M2 = Rinse pump
M4 = Upper arms wash pump
M5 = Lower arms wash pump
M6 = CU fan motor
M7 = Wash pump
M8 = Prewash pump
M10 = Upper arms prewash pump
M11 = Lower arms prewash pump
ABV = Air Break Valve
YV1 = Air-Gap filling solenoid valve (20 l/min)
YV2 = Duo-Rinse tank drain solenoid valve
E6.2
Installation diagrams
The following installation diagrams give the machine overall dimensions and position of water and electrical connec-
tions, as well as the position of the surround elements such as walls and extractor hoods.
IMPORTANT!
The extractor hood is installed to remove the steam emitted by the machine. The hood air delivery
must be calculated taking into account the machine model, the type of installation and the work
environment where installed. However, an air delivery of not greater than 300 m
mended.
IMPORTANT!
In particular, make sure to position the possible extractor hood at a distance of not less than 400
mm from the machine so as not to compromise machine operation.
The hood is represented in the diagrams with the symbol:
Also, the equipment must be installed at a distance of not less than 50 mm from the wall so as not to affect correct
ventilation of internal components.
The wall is represented in the diagrams with the symbol:
Plumbing circuit diagram, dishwashers - 300 racks/h with CU
Max 35°C
M11
YV17
YV15
YV16
180 m
55-65°C
M4
YV5
YV4
YV3 = Wash tank water filling solenoid valve (20 l/min)
YV4 = Wash pump discharge solenoid valve
YV5 = Wash tank drain solenoid valve
YV6 = Wash or prewash tank water filling solenoid valve (20 l/min)
YV7 = Wash or prewash pump discharge solenoid valve
YV8 = Wash or prewash tank drain solenoid valve
YV9 = Prewash tank water filling solenoid valve (20 l/min)
YV10 = Prewash pump discharge solenoid valve
YV11 = Prewash tank drain solenoid valve
YV12 = Prewash tank water filling solenoid valve (20 l/min)
YV13 = Prewash pump discharge solenoid valve
YV14 = Prewash tank drain solenoid valve
YV15 = Prewash tank water filling solenoid valve (20 l/min)
YV16 = Prewash pump discharge solenoid valve
YV17 = Prewash tank drain solenoid valve
3
/h
YV1
M6
ABV
M2
ABV
C
80-90°C
60-70°C
M1
M5
YV2
YV3
A
B
3
/h is recom-
25