Dosing Valve Manifold Rebuild
Order Kit 24H254 (see page 59) or Acid Kit 26A187 (see
page 61). Use all parts in the kit.
1. Follow Steps 1 - 5 in Remove Dosing Valve
Stacks, page 28.
2. Remove fitting (710) and o-ring (708).
3. Remove the dosing valve (705), then remove seat
(703) and o-rings (702 and 704) from each side of
each manifold (701, 706).
4. 3-Color Systems. Remove the spacer (707) and
o-rings (708 and 709) from between the two mani-
folds (706).
5. 3-Color Systems. Install new o-ring (708) on fitting
(710). Install fitting on bottom of 3-color manifold
(701).
NOTE: Relieve spring tension prior to installing the valve
(705) into the manifold (701 or 706).
6. Install the small o-ring (702), the seat retainer (703)
and the large o-ring (704) into the manifold, then
install the valve (705). Torque to 35-40 ft-lb (47-54
N•m). Repeat for each valve.
7. 3-Color Systems. Install new o-ring (708) on the
spacer (707). Install new o-ring (709) on the bottom
of the 1-color manifold (706). Align manifolds (701
and 706). Install four screws (711). Torque to 8-10
ft-lb (11-14 N•m).
8. Use four bolts (52) and washers (53) to reattach the
valve stacks (4, 108 if present).
9. Reconnect fluid lines. See F
10. Reconnect air lines. See System Pneumatic Sche-
matic, pages 64- 65. See also the Tubing Chart
and Diagrams, page 43 for pump-based systems or
page 51 for meter-based systems.
3A0870S
. 21, page 28.
IG
706
702
703
704
705
708
710
F
. 23. Rebuild Dosing Valve Stacks
IG
Service
711
708
707
709
712
701
ti16302a
29