SETUP HVAC TYPE

1. After HAC is displayed, press MODE.
2. Set the HVAC type desired using the UP/DOWN arrow
buttons to choose one of the following options:
:
Not Defined
00
: 4 pipe fan coil unit
FC4
: 2 pipe fan coil unit with W2
FW2
: 2 pipe fan coil unit
FC2
: PTAC unit
PAC
: Heat Pump B with W2 assist
HbW
: Heat Pump B with W2 replace
HpB
: Heat Pump O with W2 assist
HoW
: Heat Pump O with W2 replace
HpO
3. Press MODE to accept the value. The unit beeps to con-
firm the value has been set.
4. The display will show - -. Press the DOWN arrow button
to display the Fan speed (FAN) menu.

SETUP FAN SPEED

1. Once FAN is displayed, use the Up/DOWN arrow buttons
to choose the fan speed:
: Not Defined
00
: Low Speed (single speed)
Lo
: Low / High
LH
:Low / Medium* / High
LMh
*For heat pump models utilizing reversing valve, medium
heat and medium fan speed will not be available.
2. Press MODE to execute the setting, the unit beeps to con-
firm it is set.
36-00012—01

EXIT INITIALIZATION MODE

When setup is complete, exit INITIALIZATION MODE by
pressing the F/C key.
are stored in memory, the unit reboots and begins operating the
HVAC equipment as configured.

RESETTING INITIALIZATION MODE

If the user needs to return to the settings made in
INITIALIZATION MODE, do the following:
1. Enter SERVICE MODE:
2. 1. Press and hold F/C.
3. 2. Press and hold MODE.
4. 3. Press and hold FAN.
5. 4. Release F/C.
6. Use the UP/DOWN arrow buttons to display
press MODE.
7. Use the DOWN button to select
8. Press FAN.
9. The unit will reset, clear all previous values, and enter INI-
TIALIZATION MODE again.
4
is displayed, indicating the setup values
Str
.
255
then
rst,