Specialty Fan Wiring - Timer - QuietCool AFR SMT-2.0 Owner's Manual

Ower gable mount attic fan
Table of Contents

Advertisement

3.3 Specialty Fan Wiring - Timer

For wiring of a Specialty Series Fan with a timer. This wiring method works with all of our Specialty Series fans.
1. For this installation, you will need a 2 & 3 wire Romex, and an 8 Hour Timer.
2. Begin wiring the timer. From your 3 wire Romex, using a wire nut, tie the two red wires together, the
two white wires together, the two black wires together, and the two ground wires together.
3. Open up the junction box that is connected to the fan. Bring your 2 wire and 3 wire into the junction
box.
4. Tie the white common wires from the fan, the power source, and the timer together. Then, using the
green ground screw, ground the green wire from the fan to the handy box.
5. With a wire nut, tie the black wire from the fan to the red wire from the timer.
6. Then, tie the black wire from the power source to the black wire from the timer.
7. Lastly, tie the copper ground wire from the power source to the copper ground wire from the timer.
Figure 3.3A
®
®
ADVANCED ATTIC GABLE FANS
ADVANCED ATTIC GABLE FANS
Specialty Series Fan
Specialty Series Fan
Power
Power
Source
Source
10
Ground the fan to the junction box
Ground the fan to the junction box
using the green ground screw
using the green ground screw
Junction
Junction
Box
Box
14-2 Wire
14-2 Wire
14-2 Wire
14-2 Wire
Bare Copper Wires Tied
Bare Copper Wires Tied
Together
Together
8 HOUR
8 HOUR
Match Wire
Match Wire
4 HOUR
4 HOUR
Colors Together
Colors Together
2 HOUR
2 HOUR
1 HOUR
1 HOUR
HOLD
HOLD
QUIETCOOLSYSTEMS.COM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm es-2200

Table of Contents