How To Operate Your Ceiling Fan - Fanimation DUPLEX FPD6254GR Manual

Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT:
1.
Using a full range dimmer switch
(not included) to control fan speed will damage the fan.
To reduce the risk of fire or electrical shock, do not use
a full range dimmer switch to control the fan speed.
(Figure 1)
2. Restore electrical power to the outlet box by turning
the electricity on at the main fuse box. (Figure 2)
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until the blades are in place. Noise and
fan damage could result.
NOTE: The fan's receiver features an automatic learning
function. There are no frequency switches on the receiver
unit. The receiver will automatically scan the frequency
from the hand held control if any changes are made.
The frequency settings should only be changed in the
case of interference or if multiple ceiling fans with the
same type of control system are installed in the same
structure.
3. To make fan operational, install 23A/12V battery
(included) in hand-held remote transmitter, with fan
power off. Then follow the remote code setting process.
(If not used for long periods of time, remove battery to
prevent damage to transmitter). Store the remote away
from excessive heat or humidly. (Figure 3)
4. Remote Control Setting and Speed (RPM)
Setting Process : (Figure 4)
1. When powering on your fan, do not press any
button(s) before pressing the "SET" button,
otherwise the learning process will fail. If you press
a button before the "Set" button, please turn the
power off, then back on, and start the process over.
2. After installing the unit and restoring power to
your fan, press and hold the "SET" button 1-5
seconds. You must press the "SET" button within 60
seconds of restoring power to the fan.
3. The fan will start to run and begin the control
setting process.
4. DO NOT press any button(s) after pressing the SET
button and while the fan is programming or it will fail
to program. The fan will run in both directions for a
total of approximately 5 minutes.
5. When the fan stops after approximately 5 minutes
the control and speed setting process is complete.
The fan is now ready for normal use.

How to Operate Your Ceiling Fan

WARNING
For illustrative purposes only-not
intended to cover all types of controls
NOTE: If you want to change the blades: turn
power off→change the blades→turn power on
→redo the remote control setting process.
14
Figure 1
MAIN FUSE BOX
Figure 2
Figure 3
Figure 4

Advertisement

Chapters

Table of Contents
loading

Table of Contents