User's Guide
❏ Windows 8.1/Windows 8
Start screen > Apps > Epson > Epson Scan 2 Utility.
❏ Windows 7
Click the start button, and then select All Programs (or Programs) > EPSON > Epson Scan 2 > Epson
Scan 2 Utility.
❏ Mac OS
Select Go > Applications > EPSON Software > Epson Scan 2 Utility.
4. Click the Maintenance tab.
5. Click the Cleaning button.
Cleaning starts. Wait about 30 seconds.
The Cleaning sheet is ejected automatically when cleaning is complete.
Try repeating this procedure if the scanner is not cleaned at the first attempt.
Note:
❏ If dirt still remains, try using the Cleaning sheet (wet) sold as a Maintenance Sheet in the Epson store. Remove the
Cleaning sheet (wet) from its bag, unfold it, and then follow the same steps as when cleaning the product using the
Cleaning sheet. The Cleaning sheet (wet) can only be used once. If you cannot clean the product using the Cleaning sheet
(wet), contact your Epson dealer. Do not disassemble your product. The best before date for the Cleaning sheet (wet) is
approximately three years from the production date printed on the package.
❏ The Cleaning sheet, Cleaning sheet (wet), and Calibration sheet are available as a Maintenance Sheet from your nearest
Epson store.
❏ The Cleaning sheet can be used more than once. However, if it begins to lose its effect, purchase a new Cleaning sheet.
❏ Cleaning does not start if the product's batteries are running low.
Related Information
"Maintenance Sheet Codes" on page 12
&
Scanner Adjustment Using the Calibration Sheet
You can adjust the scanned image quality using the Calibration sheet supplied with your product.
Perform calibration in the following situations.
❏ The results are blurred
❏ The colors differ from the original
❏ The density differs from the original
❏ Vertical lines appear in the results
1. Make sure that the product is connected to your computer and turn on.
Maintenance
39
Need help?
Do you have a question about the ES-50 and is the answer not in the manual?