Download Print this page

Cochlear Baha 5 SuperPower User Manual page 6

Superpower sound processor
Hide thumbs Also See for Baha 5 SuperPower:

Advertisement

Replace the battery
Remove the battery
See figure
2
Twist the battery module to remove it from the
processing unit.
Attach the battery
See figure
2
Align the battery module to the processor socket
to fit the parts together. Twist the battery module
as shown to attach the parts. The processor will
turn on automatically.
Lock/Unlock the battery
See figure
9
1
To increase tamper resistance, push the lock to
the far left with your battery cover locking tool
to lock the battery module.
Push the lock to the far right to unlock the
2
battery module.
Charge battery modules
See figure
10
1
Angle and fit the rechargeable battery module
into a socket on the Cochlear Nucleus
Battery
®
Charger.
Twist clockwise to connect.
2
3
Connect the battery charger to the power
adaptor and plug into mains power.
General processor care
Your Baha sound processor is a delicate electronic
device. Follow these guidelines to keep it in proper
working order:
• When not in use, turn off your sound processor
and store it free from dust and dirt.
• If you will not be using your sound processor
for a long period, remove the battery. Remove
your sound processor before applying hair
conditioners, mosquito repellent and or similar
products
8
Water, sand and dirt
See figure
11
Your sound processor is resistant to water, sand
and dust. However, it is still a precision electronic
device so the following precautions should be
taken.
If your processor ever gets wet, dry it with a
1
soft cloth, change the microphone protectors
and place it in the dry aid kit provided by
Cochlear for 8 hours.
2
If sand or dirt ever enter the processor, shake
the components carefully to remove it and
change the microphone protectors.
Using Share the Experience
See figure
12
Family members and friends can "share the
experience" of bone conduction hearing. The test
rod can be used by others to hear with the sound
processor.
To use the test rod:
1
Turn on your sound processor and snap the
Actuator unit onto the test rod using the tilt
technique.
2
Place the Sound Processing unit on the ear.
Hold the rod against the skull bone behind an
ear. Plug both ears and listen.
Note: Your hearing care professional may have
disabled some or all of the audible and/or visible
indicators.
Wear a Snugfit
The Snugfit holds your sound processor more
securely in place than an earhook alone. It gives
carers easy access to controls and accessories and
is available in large, medium and tamper resistant
(small).
Attach a Snugfit
See figure
13
1
Press firmly on the top of the earhook with
your thumb to click it off the sound processor.
Click your Snugfit into place
2
Carefully bend the lower part into shape to suit
3
your ear.
Remove a Snugfit
4
Remove your Snugfit by clicking it off the
processor.
Wear a Mic Lock
See figure
14
The Mic Lock helps hold the processor securely on
the ear.
To attach the Mic Lock the first time:
Push the Mic Lock band onto the processor
1
with the tubing facing forward.
2
Place the processor on your ear and bring the
tubing up to the earhook.
3
Trim the tubing to a length that will hold the
processor firmly in place without discomfort.
Do not cut it too short.
4
Soften the end of the tubing in warm water
and push it onto the tip of your earhook.
Let the tubing cool before wearing
5
English
Attach and remove processor covers
See figure
15
1
To attach, slide the cover onto the processor.
2
To remove, pull the cover away from the
processor.
Note: Snugfit, Mic Lock, and Processor covers are
available as accessories. For more information,
ask your hearing care professional or visit www.
cochlear.com
Replace microphone protectors
See figure
16
Replace your microphone protectors every
three months, whenever they look dirty or
whenever you notice any loss in sound
quality. Always replace both microphone
protectors at the same time.
Remove microphone protectors
1
Remove the protective cap from the
Microphone Protector Removal Tool.
2
Push the tip of the tool into the middle of the
microphone protector.
3
Turn the tool 90° clockwise
4
Lift out the microphone protector and discard.
Repeat steps 2 to 4 to remove the other micro-
phone protector.
9

Advertisement

loading