the adjacent room and it must be provided with a solid and condensation collection chamber under the
entrance, accessible through the sealed metal gate.
• The inner section of the chimney flue can be round (the best one) or square and the jointed sides must have
a minimum radius of 20 mm.
• The section dimension must be minimum Ø150 mm and maximum Ø240 mm.
• Made the efficiency of the chimney flue overhauled by an expert stove-repairer and if necessary cover the
chimney flue with materials in compliance with current regulations.
• The flue system must be placed on the roof.
• The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an
example of label:
8.4

HEIGHT-DEPRESSION

The depression (draught) of a chimney flue depends also on its height. Check the depression with the values
provided at . Minimum height 3,5 meters.
8.5

MAINTENANCE

• The chimney flue must be cleaned, since the soot and unburnt oil deposits reduce its section so blocking the
draught. In great quantities they can flare up.
• The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed
and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the
stove-manufacturer and the directives of your insurance company.
• In case of doubts, please follow the most restrictive regulations.
• Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once
a week. The chimney sweep has to release a written declaration about the security of the system.
• Not cleaning compromise safety.
8.6

CHIMNEY POT

The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see Fig. 4 page 7.
• The hole width for fumes exhaust must be the double of the chimney flue width and fitted in a way that the
fume exhaust is assured also in case of wind.
• It should prevent the infiltration of rain, snow and animals.
• The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by
CARINA - DORA
Fig. 2 - Example of label
Fig. 3 - Anti-wind chimney pots
EN
7