plug which enables an easy periodic cleaning of the pipes.
• Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.
• It is forbidden to connect more appliances to the same fume conduit.
EN
• It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
• It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also at open
top.
• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
• The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible
components.
• The fume conduit must be connected with stove exhaust in a fixed and tight manner, and if required with the
insertion of a damper.
8.10

EXAMPLES OF CORRECT INSTALLATION

• Chimney flue installation Ø150 mm with an enlarged drilling for pipe transit.
10
Fig. 7 - Example 1
LEGEND
Fig. 8 page 10
1
Insulating material
2
Reduction from Ø150 to Ø120 mm
3
Inspection plug
4
Minimum safety distance = 0,5 mt
5
Damper
CARINA - DORA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dora 9,5 kw